• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

449.4.2.7 Plumbing Standards

2020 FBC - Building, 7th edition > 4 Special Detailed Requirements Based on Occupancy and Use > 449 Hospitals > 449.4 Physical Plant Requirements for Disaster Preparedness of New Hospital Construction > 449.4.2 Disaster Preparedness Construction Standards > 449.4.2.7 Plumbing Standards
JUMP TO FULL CODE CHAPTER

449.4.2.7.1

There shall be an independent on-site supply (i.e., water well) or on-site storage capability (i.e., empty water storage containers or bladders) of potable water at a minimum quantity of 3 gallons (14 L) per in-patient and one gallon (3.7 L) per facility staff and other personnel in the new facility or wing or floor addition to an existing facility per day during and immediately following a disaster. For planning purposes, the number of in-patients, staff and other personnel shall be determined in writing by the facility and submitted to AHCA. Hot water in boilers or tanks shall not be counted to meet this requirement.

449.4.2.7.2

The facility shall determine what amount of water will be sufficient to provide for patient services, and shall maintain an on-site supply or on-site storage of the determined amount.

449.4.2.7.3

When utilized to meet the minimum requirements of this rule, selected system appurtenances such as water pressure maintenance house pumps, and emergency water supply well pumps shall take power from the emergency power supply system(s).

Related Code Sections


449.4.2.7 Special Detailed Requirements Based on Use and Occupancy, Plumbing Standards
There shall be an independent on-site supply (i.e., water well) or on-site storage capability (i.e., empty water storage containers or bladders ...
2017 FBC - Building, 6th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 449 Hospitals > 449.4 Physical Plant Requirements for Disaster Preparedness of New Hospital Construction > 449.4.2 Disaster Preparedness Construction Standards > 449.4.2.7 Plumbing Standards
449.4.2.7 Special Detailed Requirements Based on Occupancy and Use, Plumbing Standards
There shall be an independent on-site supply (i.e., water well) or on-site storage capability (i.e., empty water storage containers or bladders ...
2020 FBC - Building, 7th edition > 4 Special Detailed Requirements Based on Occupancy and Use > 449 Hospitals > 449.4 Physical Plant Requirements for Disaster Preparedness of New Hospital Construction > 449.4.2 Disaster Preparedness Construction Standards > 449.4.2.7 Plumbing Standards
449.4.2.7 Special Detailed Requirements Based on Use and Occupancy, Plumbing Standards
There shall be an independent on-site supply (i.e., water well) or on-site storage capability (i.e., empty water storage containers or bladders ...
2014 FBC - Building, 5th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 449 Hospitals > 449.4 Physical Plant Requirements for Disaster Preparedness of New Hospital Construction > 449.4.2 Disaster Preparedness Construction Standards > 449.4.2.7 Plumbing Standards
450.4.2.7 Special Detailed Requirements Based on Use and Occupancy, Plumbing Standards
There shall be an independent on-site supply (i.e., water well) or on-site storage capability (i.e., empty water storage containers or bladders ...
2017 FBC - Building, 6th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 450 Nursing Homes > 450.4 Physical Plant Requirements for Disaster Preparedness of New Nursing Home Construction > 450.4.2 Disaster Preparedness Construction Standards > 450.4.2.7 Plumbing Standards
450.4.2.7 Special Detailed Requirements Based on Occupancy and Use, Plumbing Standards
There shall be an independent on-site supply (i.e., water well) or on-site storage capability (i.e., empty water storage containers or bladders ...
2020 FBC - Building, 7th edition > 4 Special Detailed Requirements Based on Occupancy and Use > 450 Nursing Homes > 450.4 Physical Plant Requirements for Disaster Preparedness of New Nursing Home Construction > 450.4.2 Disaster Preparedness Construction Standards > 450.4.2.7 Plumbing Standards
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING