Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with 213.2 shall comply with 213.3.
213.3.1 Toilet Compartments
Where toilet compartments are provided, at least one toilet compartment shall comply with 604.8.1.  In addition to the compartment required to comply with 604.8.1, at least one compartment shall comply with 604.8.2 where six or more toilet compartments are provided, or where the combination of urinals and water closets totals six or more fixtures.
Advisory 213.3.1 Toilet Compartments.  A toilet compartment is a partitioned space that is located within a toilet room, and that normally contains no more than one water closet.  A toilet compartment may also contain a lavatory.  A lavatory is a sink provided for hand washing.  Full-height partitions and door assemblies can comprise toilet compartments where the minimum required spaces are provided within the compartment.
213.3.2 Water Closets
Where water closets are provided, at least one shall comply with 604.
213.3.3 Urinals
Where more than one urinal is provided, at least one shall comply with 605.
213.3.4 Lavatories
Where lavatories are provided, at least one shall comply with 606 and shall not be located in a toilet compartment.
213.3.5 Mirrors
Where mirrors are provided, at least one shall comply with 603.3.
213.3.6 Bathing Facilities
Where bathtubs or showers are provided, at least one bathtub complying with 607 or at least one shower complying with 608 shall be provided.
213.3.7 Coat Hooks and Shelves
Where coat hooks or shelves are provided in toilet rooms without toilet compartments, at least one of each type shall comply with 603.4. Where coat hooks or shelves are provided in toilet compartments, at least one of each type complying with 604.8.3 shall be provided in toilet compartments required to comply with 213.3.1.  Where coat hooks or shelves are provided in bathing facilities, at least one of each type complying with 603.4 shall serve fixtures required to comply with 213.3.6.

Related Code Sections

213.3 Scoping Requirements, Plumbing Fixtures and Accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with 213.2 shall comply with 213.3 ...
213.3.6 Scoping Requirements, Bathing Facilities
Where bathtubs or showers are provided, at least one bathtub complying with 607 or at least one shower complying with 608 shall be provided ...
213 Scoping Requirements, Toilet Facilities and Bathing Facilities
fixtures and accessories provided in a toilet room or bathing room required to comply with 213.2 shall comply with 213.3 ...
603 Plumbing Elements and Facilities, Toilet and Bathing Rooms
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap ...