• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1008.4 Play Components

2010 ADA Standards > 10 Recreation Facilities > 1008 Play Areas > 1008.4 Play Components
JUMP TO FULL CODE CHAPTER
Ground level play components on accessible routes and elevated play components connected by ramps shall comply with 1008.4.

1008.4.1 Turning Space

At least one turning space complying with 304 shall be provided on the same level as play components.  Where swings are provided, the turning space shall be located immediately adjacent to the swing.

1008.4.2 Clear Floor or Ground Space

Clear floor or ground space complying with 305.2 and 305.3 shall be provided at play components.
Advisory 1008.4.2 Clear Floor or Ground Space.  Clear floor or ground spaces, turning spaces, and accessible routes are permitted to overlap within play areas.  A specific location has not been designated for the clear floor or ground spaces or turning spaces, except swings, because each play component may require that the spaces be placed in a unique location.  Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended.  This will enhance the ability of children with disabilities to independently use the play component.
When designing play components with manipulative or interactive features, consider appropriate reach ranges for children seated in wheelchairs.  The following table provides guidance on reach ranges for children seated in wheelchairs.  These dimensions apply to either forward or side reaches.  The reach ranges are appropriate for use with those play components that children seated in wheelchairs may access and reach.  Where transfer systems provide access to elevated play components, the reach ranges are not appropriate.
Children's Reach Ranges
Forward or Side ReachAges 3 and 4Ages 5 through 8Ages 9 through 12
High (maximum) 36 in (915 mm) 40 in (1015 mm) 44 in (1120 mm)
Low (minimum) 20 in (510 mm) 18 in (455 mm) 16 in (405 mm)

1008.4.3 Play Tables

Where play tables are provided, knee clearance 24 inches (610 mm) high minimum, 17 inches deep (430 mm) minimum, and 30 inches (760 mm) wide minimum shall be provided. The tops of rims, curbs, or other obstructions shall be 31 inches (785 mm) high maximum.

EXCEPTION: Play tables designed and constructed primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required by 1008.4.2 is arranged for a parallel approach.

1008.4.4 Entry Points and Seats

Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground space.

EXCEPTION: Entry points of slides shall not be required to comply with 1008.4.4.

1008.4.5 Transfer Supports

Where play components require transfer to entry points or seats, at least one means of support for transferring shall be provided.

Related Code Sections


1008.4 Recreation Facilities, Play Components
Ground level play components on accessible routes and elevated play components connected by ramps shall comply with 1008.4 ...
2010 ADA Standards > 10 Recreation Facilities > 1008 Play Areas > 1008.4 Play Components
240.2 Scoping Requirements, Play Components
Where provided, play components shall comply with 240.2 ...
2010 ADA Standards > 2 Scoping Requirements > 240 Play Areas > 240.2 Play Components
206.2.17.1 Scoping Requirements, Ground Level and Elevated Play Components
At least one accessible route shall be provided within the play area.  The accessible route shall connect ground level play components required ...
2010 ADA Standards > 2 Scoping Requirements > 206 Accessible Routes > 206.2 Where Required > 206.2.17 Play Areas > 206.2.17.1 Ground Level and Elevated Play Components
240.2.1.2 Scoping Requirements, Additional Number and Types
Where elevated play components are provided, ground level play components shall be provided in accordance with Table 240.2.1.2 and shall comply ...
2010 ADA Standards > 2 Scoping Requirements > 240 Play Areas > 240.2 Play Components > 240.2.1 Ground Level Play Components > 240.2.1.2 Additional Number and Types
1008.4.3 Recreation Facilities, Play Tables
Where play tables are provided, knee clearance 24 inches (610 mm) high minimum, 17 inches deep (430 mm) minimum, and 30 inches (760 mm) wide minimum ...
2010 ADA Standards > 10 Recreation Facilities > 1008 Play Areas > 1008.4 Play Components > 1008.4.3 Play Tables
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING