2.15.15 Platform Side Braces
Go To Full Code Chapter
Where side bracing and similar members are attached to car-frame uprights, the reduction in area of the upright shall not reduce the strength of the upright below that required by Section 2.15.
Related Code Sections
2.15.15 Electric Elevators, Platform Side Braces
Where side bracing and similar members are attached to car-frame uprights, the reduction in area of the upright shall not reduce the strength ...
5.1.12 Special Application Elevators, Car Frames and Platforms
The entrance side of the platform shall be provided with smooth ...
7.2.2 Dumbwaiters and Material Lifts, Car Frames and Platforms
Car frames and platforms shall comply with Section 2.15, except as modified by 7.2.2.1 through 7.2.2.14 ...
5.3.1.10.2 Special Application Elevators, Platforms
) Platform Guards (Aprons). Where the elevator is equipped with a two-way leveling device, the entrance side(s) of the platform shall be provided ...
5.6.1.15.1 Special Application Elevators, Platforms
tipping of the platform when it is at the highest upper landing level. (c) The car platform shall be provided with metal aprons or guards on all ...