403.11 Plastic Pipe, Joints and Fittings
JUMP TO FULL CODE CHAPTER
Plastic pipe, tubing and fittings shall be joined in accordance with the manufacturer's instructions. Such joint shall comply with the following:
- The joint shall be designed and installed so that the longitudinal pull-out resistance of the joint will be greater than or equal to the tensile strength of the plastic piping material.
- Heat-fusion joints shall be made in accordance with qualified procedures that have been established and proven by test to produce gas-tight joints as strong as or stronger than the pipe or tubing being joined. Joints shall be made with the joining method recommended by the pipe manufacturer. Heat fusion fittings shall be marked "ASTM D2513."
- Where compression-type mechanical joints are used, the gasket material in the fitting shall be compatible with the plastic piping and with the gas distributed by the system. An internal tubular rigid stiffener shall be used in conjunction with the fitting. The stiffener shall be flush with the end of the pipe or tubing and shall extend to or beyond the outside end of the compression fitting when installed. The stiffener shall be free of rough or sharp edges and shall not be a force-fit in the plastic. Split tubular stiffeners shall not be used.
- Plastic piping joints and fittings for use in liquefied petroleum gas piping systems shall be in accordance with NFPA 58.
Related Code Sections
403.11 Gas Piping Installations, Plastic Pipe, Joints and Fittings
Plastic pipe, tubing and fittings shall be joined in accordance with the manufacturer's instructions. Such joint shall comply with the following ...
Fuel Gas Code 2018 of Kansas > 4 Gas Piping Installations > 403 (IFGS) Piping Materials > 403.11 Plastic Pipe, Joints and Fittings
G2414.11 Fuel Gas, (403.11) Plastic Piping, Joints and Fittings
Plastic pipe, tubing and fittings shall be joined in accordance with the manufacturers' instructions. Such joints shall comply with the following ...
Residential Code 2018 of Kansas > 24 Fuel Gas > G2414 (403) Piping Materials > G2414.11 (403.11) Plastic Piping, Joints and Fittings
M2105.14 Hydronic Piping, PVC Plastic Pipe
Joints between PVC plastic pipe or fittings shall be solvent-cemented in accordance with Section P2906.9.1.4. Threaded joints between fittings ...
Residential Code 2018 of Kansas > 21 Hydronic Piping > M2105 Ground-Source Heat-Pump System Loop Piping > M2105.14 PVC Plastic Pipe
705.16.4 Sanitary Drainage, Plastic Pipe or Tubing to Other Piping Material
Joints between different types of plastic pipe shall be made with an approved adapter fitting, or by a solvent cement joint only where a single ...
Plumbing Code 2018 of Kansas > 7 Sanitary Drainage > 705 Joints > 705.16 Joints Between Different Materials > 705.16.4 Plastic Pipe or Tubing to Other Piping Material
P3003.13.4 Sanitary Drainage, Plastic Pipe or Tubing to Other Piping Material
Joints between different types of plastic pipe shall be made with an approved adapter fitting or by a solvent-cement joint only where a single ...
Residential Code 2018 of Kansas > 30 Sanitary Drainage > P3003 Joints and Connections > P3003.13 Joints Between Different Materials > P3003.13.4 Plastic Pipe or Tubing to Other Piping Material