• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

404.17 Plastic Pipe

2014 FBC - Fuel Gas, 5th edition > 4 Gas Piping Installations > 404 (IFGC) Piping System Installation > 404.17 Plastic Pipe
JUMP TO FULL CODE CHAPTER
The installation of plastic pipe shall comply with Sections 404.17.1 through 404.17.3.

404.17.1 Limitations

Plastic pipe shall be installed outdoors underground only. Plastic pipe shall not be used within or under any building or slab or be operated at pressures greater than 100 psig (689 kPa) for natural gas or 30 psig (207 kPa) for LP-gas.

Exceptions:
  1. Plastic pipe shall be permitted to terminate above ground outside of buildings where installed in premanufactured anodeless risers or service head adapter risers that are installed in accordance with the manufacturer's installation instructions.
  2. Plastic pipe shall be permitted to terminate with a wall head adapter within buildings where the plastic pipe is inserted in a piping material for fuel gas use in buildings.
  3. Plastic pipe shall be permitted under outdoor patio, walkway and driveway slabs provided that the burial depth complies with Section 404.12.

404.17.2 Connections

Connections made outdoors and underground between metallic and plastic piping shall be made only with transition fittings conforming with ASTM D 2513 Category I or ASTM F 1973.

404.17.3 Tracer

A yellow insulated copper tracer wire or other approved conductor shall be installed adjacent to underground nonmetallic piping. Access shall be provided to the tracer wire or the tracer wire shall terminate above ground at each end of the nonmetallic piping. The tracer wire size shall not be less than 18 AWG and the insulation type shall be suitable for direct burial.

Related Code Sections


404.17 Gas Piping Installations, Plastic Pipe
The installation of plastic pipe shall comply with Sections 404.17.1 through 404.17.3 ...
2017 FBC - Fuel Gas, 6th edition > 4 Gas Piping Installations > 404 (IFGC) Piping System Installation > 404.17 Plastic Pipe
404.17 Gas Piping Installations, Plastic Pipe
The installation of plastic pipe shall comply with Sections 404.17.1 through 404.17.3 ...
2014 FBC - Fuel Gas, 5th edition > 4 Gas Piping Installations > 404 (IFGC) Piping System Installation > 404.17 Plastic Pipe
404.17 Gas Piping Installations, Plastic Pipe
The installation of plastic pipe shall comply with Sections 404.17.1 through 404.17.3 ...
2020 FBC - Fuel Gas, 7th edition > 4 Gas Piping Installations > 404 (IFGC) Piping System Installation > 404.17 Plastic Pipe
405.3 Gas Piping Installations, Plastic Pipe
Plastic pipe bends shall comply with the following: The pipe shall not be damaged and the internal diameter of the pipe shall not be effectively ...
2014 FBC - Fuel Gas, 5th edition > 4 Gas Piping Installations > 405 (IFGS) Piping Bends and Changes in Direction > 405.3 Plastic Pipe
405.3 Gas Piping Installations, Plastic Pipe
Plastic pipe bends shall comply with the following: The pipe shall not be damaged and the internal diameter of the pipe shall not be effectively ...
2017 FBC - Fuel Gas, 6th edition > 4 Gas Piping Installations > 405 (IFGS) Piping Bends and Changes in Direction > 405.3 Plastic Pipe
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE