• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

AR103.5.2 Plaster Finish

2015 Michigan Residential Code > R Light Straw-Clay Construction > AR103 Nonbearing Light Straw-Clay Construction > AR103.5 Wall Finishes > AR103.5.2 Plaster Finish
JUMP TO FULL CODE CHAPTER
Exterior plaster finishes shall be clay plaster or lime plaster. Interior plaster finishes shall be clay plaster, lime plaster or gypsum plaster. Plasters shall be permitted to be applied directly to the surface of the light straw-clay walls without reinforcement, except that the juncture of dissimilar substrates shall be in accordance with Section AR103.5.4. Plasters shall have a thickness of not less than 1/2 inch (12.7 mm) and not more than 1 inch (25 mm) and shall be installed in not less than two coats. Exterior clay plaster shall be finished with a limebased or silicate-mineral coating.

Related Code Sections


722.4.1.2 Fire and Smoke Protection Features, Plaster Finishes
Where plaster is applied to the wall, the total fire-resistance rating shall be determined by the formula: R = ( R n 0.59 + pl ) 1.7 ...
2015 Michigan Building Code > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.4 Clay Brick and Tile Masonry > 722.4.1 Masonry Walls > 722.4.1.2 Plaster Finishes
AR103.5.2 Light Straw-Clay Construction, Plaster Finish
Exterior plaster finishes shall be clay plaster or lime plaster. Interior plaster finishes shall be clay plaster, lime plaster or gypsum plaster ...
2015 Michigan Residential Code > R Light Straw-Clay Construction > AR103 Nonbearing Light Straw-Clay Construction > AR103.5 Wall Finishes > AR103.5.2 Plaster Finish
2512.9 Gypsum Board, Gypsum Panel Products and Plaster, Finish Coats
Cement plaster finish coats shall be applied over base coats that have been in place for the time periods set forth in ASTM C926. The third or finish ...
2015 Michigan Building Code > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2512 Exterior Plaster > 2512.9 Finish Coats
AS104.4.1 Strawbale Construction, Plaster and Membranes
Plaster shall be applied directly to strawbale walls to facilitate transpiration of moisture from the bales, and to secure a mechanical bond between ...
2015 Michigan Residential Code > S Strawbale Construction > AS104 Finishes > AS104.4 Plaster > AS104.4.1 Plaster and Membranes
719.5 Fire and Smoke Protection Features, Plaster Alternatives for Concrete
floors and 1 inch (25 mm) in reinforced concrete columns in addition to the plaster finish. The concrete base shall be prepared in accordance ...
2015 Michigan Building Code > 7 Fire and Smoke Protection Features > 719 Fire-Resistance Requirements for Plaster > 719.5 Plaster Alternatives for Concrete
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE