• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

719.5 Plaster Alternatives for Concrete

2014 FBC - Building, 5th edition > 7 Fire and Smoke Protection Features > 719 Fire-Resistance Requirements for Plaster > 719.5 Plaster Alternatives for Concrete
JUMP TO FULL CODE CHAPTER

In reinforced concrete construction, gypsum plaster or Portland cement plaster is permitted to be substituted for 1/2 inch (12.7 mm) of the required poured concrete protection, except that a minimum thickness of 3/8 inch (9.5 mm) of poured concrete shall be provided in reinforced concrete floors and 1 inch (25 mm) in reinforced concrete columns in addition to the plaster finish. The concrete base shall be prepared in accordance with Section 2510.7.

Related Code Sections


719.5 Fire and Smoke Protection Features, Plaster Alternatives for Concrete
In reinforced concrete construction, gypsum plaster or Portland cement plaster is permitted to be substituted for 1 / 2 inch (12.7 mm ...
2014 FBC - Building, 5th edition > 7 Fire and Smoke Protection Features > 719 Fire-Resistance Requirements for Plaster > 719.5 Plaster Alternatives for Concrete
719.5 Fire and Smoke Protection Features, Plaster Alternatives for Concrete
In reinforced concrete construction, gypsum plaster or Portland cement plaster is permitted to be substituted for 1 / 2 inch (12.7 mm ...
2017 FBC - Building, 6th edition > 7 Fire and Smoke Protection Features > 719 Fire-Resistance Requirements for Plaster > 719.5 Plaster Alternatives for Concrete
719.5 Fire and Smoke Protection Features, Plaster Alternatives for Concrete
In reinforced concrete construction, gypsum plaster or Portland cement plaster is permitted to be substituted for 1 / 2 inch (12.7 mm ...
2020 FBC - Building, 7th edition > 7 Fire and Smoke Protection Features > 719 Fire-Resistance Requirements for Plaster > 719.5 Plaster Alternatives for Concrete
R703.6.2 Wall Covering, Plaster
Plastering with portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two ...
2014 FBC - Residential, 5th edition > 7 Wall Covering > R703 Exterior Covering > R703.6 Exterior Plaster > R703.6.2 Plaster
R703.7.2 Wall Covering, Plaster
Plastering with portland cement plaster shall be not less than three coats where applied over metal lath or wire lath and shall be not less than two ...
2017 FBC - Residential, 6th edition > 7 Wall Covering > R703 Exterior Covering > R703.7 Exterior Plaster > R703.7.2 Plaster
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE