// CODE SNIPPET
23-451 Planting Requirement
Go To Full Code Chapter
R1 R2 R3 R4 R5
In the districts indicated, a minimum percentage of the area of the front yard shall be planted, which shall vary by street frontage of the zoning lot as set forth in the following table. For the purposes of this Section, the front yard shall include the entire area between all street walls of the building and their prolongations and the street line. Planted areas shall be comprised of any combination of grass, groundcover, shrubs, trees or other living plant material, and shall have a minimum dimension of one foot, exclusive of any bounding walls. Any planted area within a driveway or parking space shall not qualify towards meeting the minimum planting requirements of this Section. For through lots or corner lots, the planting requirement of this Section shall be applied separately to each street frontage. For corner lots, planted areas of overlapping portions of front yards shall only be counted towards the planting requirement of one front yard. For zoning lots with multiple building segments, the planting requirement of this Section shall be applied separately to the entire area between the street wall of each building segment and the street line.
Where multiple buildings on a single zoning lot front upon the same street, the planting requirements of this Section shall be determined by the street frontage allocated to the area occupied by each such building and applied separately to the entire area between the street line and the street wall of each building and its prolongation. The allocation of planting requirements to open areas between buildings shall be determined by dividing such open area evenly, with an equal portion attributed to each building on both sides of such open area.
Any zoning lot occupied by a building constructed after April 30, 2008, shall provide planted areas in accordance with the provisions of this Section. Any zoning lot occupied by a building constructed prior to such date shall not be altered in any way that will either create new non-compliance or increase the degree of non-compliance with the provisions of this Section.
Street frontage of zoning lot, street wall width of building segment, or street frontage allocated to each of multiple buildings on a single zoning lot, as applicable | Percentage of front yard to be planted (minimum) |
Less than 20 feet | 20 |
20 to 34 feet | 25 |
35 to 59 feet | 30 |
60 feet or greater | 50 |
Upcodes Diagrams
Related Code Sections
22.10.1.1 Special Occupancy Requirements,
designed to be not less than that required by NFPA 13 for Extra Hazard Group 1 with a minimum design area of 2500 ft2 (232.26 m2). [51A:11.2.1.2] ...
22.12.1.1 Special Occupancy Requirements,
systems involved in the maximum single incident expected in the plant, including monitor nozzles, at their design flow and pressure. [59:13.4.2] ...
22.28.2.1 Special Occupancy Requirements,
Sprinkler systems and manual hose station standpipes shall be connected to the plant fire protection water main so that a single active failure ...
22.29.1.1 Special Occupancy Requirements, Hydraulic Control Systems
Fixed fire protection for this equipment, where provided, should be as follows:
Automatic wet pipe sprinkler systems utilizing a design density ...