• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.421(d) Planning and Assessment

OSHA 1910 General Industry > T Commercial Diving Operations > 1910.421 Pre-Dive Procedures > 1910.421(d) Planning and Assessment
JUMP TO FULL CODE CHAPTER
Planning of a diving operation shall include an assessment of the safety and health aspects of the following:

1910.421(d)(1) Diving Mode

1910.421(d)(2) Surface and Underwater Conditions and Hazards

1910.421(d)(3) Breathing Gas Supply (Including Reserves)

1910.421(d)(4) Thermal Protection

1910.421(d)(5)

Diving equipment and systems;

1910.421(d)(6)

Dive team assignments and physical fitness of dive team members (including any impairment known to the employer);

1910.421(d)(7)

Repetitive dive designation or residual inert gas status of dive team members;

1910.421(d)(8)

Decompression and treatment procedures (including altitude corrections); and

1910.421(d)(9) Emergency Procedures

Related Code Sections


1910.421(d) Commercial Diving Operations, Planning and Assessment
Planning of a diving operation shall include an assessment of the safety and health aspects of the following ...
OSHA 1910 General Industry > T Commercial Diving Operations > 1910.421 Pre-Dive Procedures > 1910.421(d) Planning and Assessment
1910.421(d)(6) Commercial Diving Operations,
Dive team assignments and physical fitness of dive team members (including any impairment known to the employer ...
OSHA 1910 General Industry > T Commercial Diving Operations > 1910.421 Pre-Dive Procedures > 1910.421(d) Planning and Assessment > 1910.421(d)(6)
1910.421(d)(7) Commercial Diving Operations,
Repetitive dive designation or residual inert gas status of dive team members ...
OSHA 1910 General Industry > T Commercial Diving Operations > 1910.421 Pre-Dive Procedures > 1910.421(d) Planning and Assessment > 1910.421(d)(7)
1910.421(d)(8) Commercial Diving Operations,
Decompression and treatment procedures (including altitude corrections ...
OSHA 1910 General Industry > T Commercial Diving Operations > 1910.421 Pre-Dive Procedures > 1910.421(d) Planning and Assessment > 1910.421(d)(8)
1910.421(d)(9) Commercial Diving Operations, Emergency Procedures
OSHA 1910 General Industry > T Commercial Diving Operations > 1910.421 Pre-Dive Procedures > 1910.421(d) Planning and Assessment > 1910.421(d)(9) Emergency Procedures
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE