• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

G2417.7.2 (406.7.2) Piping Systems Allowed to Be Purged Indoors or Outdoors

Residential Code 2015 of Utah > 24 Fuel Gas > G2417 (406) Inspection, Testing and Purging > G2417.7 (406.7) Purging > G2417.7.2 (406.7.2) Piping Systems Allowed to Be Purged Indoors or Outdoors
JUMP TO FULL CODE CHAPTER
The purging of piping systems shall be in accordance with the provisions of Section G2417.7.2.1 where the piping system meets both of the following:
  1. The design operating gas pressure is 2 psig (13.79 kPa) or less.
  2. The piping being purged is constructed entirely from pipe or tubing not meeting the size and length criteria of Table G2417.7.1.1.

G2417.7.2.1 (406.7.2.1) Purging Procedure

The piping system shall be purged in accordance with one or more of the following:
  1. The piping shall be purged with fuel gas and shall discharge to the outdoors.
  2. The piping shall be purged with fuel gas and shall discharge to the indoors or outdoors through an appliance burner not located in a combustion chamber. Such burner shall be provided with a continuous source of ignition.
  3. The piping shall be purged with fuel gas and shall discharge to the indoors or outdoors through a burner that has a continuous source of ignition and that is designed for such purpose.
  4. The piping shall be purged with fuel gas that is discharged to the indoors or outdoors, and the point of discharge shall be monitored with a listed combustible gas detector in accordance with Section G2417.7.2.2. Purging shall be stopped when fuel gas is detected.
  5. The piping shall be purged by the gas supplier in accordance with written procedures.

G2417.7.2.2 (406.7.2.2) Combustible Gas Detector

Combustible gas detectors shall be listed and shall be calibrated or tested in accordance with the manufacturer's instructions. Combustible gas detectors shall be capable of indicating the presence of fuel gas.

Related Code Sections


G2417.7.2 Fuel Gas, (406.7.2) Piping Systems Allowed to Be Purged Indoors or Outdoors
discharge to the outdoors. The piping shall be purged with fuel gas and shall discharge to the indoors or outdoors through an appliance burner ...
Residential Code 2015 of Utah > 24 Fuel Gas > G2417 (406) Inspection, Testing and Purging > G2417.7 (406.7) Purging > G2417.7.2 (406.7.2) Piping Systems Allowed to Be Purged Indoors or Outdoors
406.7.2 Gas Piping Installations, Piping Systems Allowed to Be Purged Indoors or Outdoors
to the outdoors. The piping shall be purged with fuel gas and shall discharge to the indoors or outdoors through an appliance burner not located ...
Fuel Gas Code 2018 of Utah > 4 Gas Piping Installations > 406 (IFGS) Inspection, Testing and Purging > 406.7 Purging > 406.7.2 Piping Systems Allowed to Be Purged Indoors or Outdoors
406.7.2 Gas Piping Installations, Piping Systems Allowed to Be Purged Indoors or Outdoors
to the outdoors. The piping shall be purged with fuel gas and shall discharge to the indoors or outdoors through an appliance burner not located ...
Fuel Gas Code 2015 of Utah > 4 Gas Piping Installations > 406 (IFGS) Inspection, Testing and Purging > 406.7 Purging > 406.7.2 Piping Systems Allowed to Be Purged Indoors or Outdoors
406.7 Gas Piping Installations, Purging
The open end of a piping system being pressure vented or purged shall discharge directly ...
Fuel Gas Code 2015 of Utah > 4 Gas Piping Installations > 406 (IFGS) Inspection, Testing and Purging > 406.7 Purging
406.7.2 Special Detailed Requirements Based on Occupancy and Use, Canopies
Canopies under which fuels are dispensed shall have a clear, unobstructed height of not less than 13 feet 6 inches (4115 mm) to the lowest projecting ...
Building Code 2018 of Utah > 4 Special Detailed Requirements Based on Occupancy and Use > 406 Motor-Vehicle-Related Occupancies > 406.7 Motor Fuel-Dispensing Facilities > 406.7.2 Canopies
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE