[F] 417.2 Piping Clearance
JUMP TO FULL CODE CHAPTER
Overhead heating pipes shall have a clearance of not less than 2 inches (51 mm) from combustible contents in the dryer.
Related Code Sections
417.2 Special Detailed Requirements Based on Occupancy and Use, Piping Clearance
Overhead heating pipes shall have a clearance of not less than 2 inches (51 mm) from combustible contents in the dryer ...
Building Code 2021 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 417 Drying Rooms > 417.2 Piping Clearance
417.2 Special Detailed Requirements Based on Occupancy and Use, Piping Clearance
Overhead heating pipes shall have a clearance of not less than 2 inches (51 mm) from combustible contents in the dryer ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 417 Drying Rooms > 417.2 Piping Clearance
18.4* Installation Requirements for Seismic Protection, Clearance
Clearance shall be provided around all piping extending through walls, floors, platforms, and foundations, including drains, fire department ...
Standard for the Installation of Sprinkler Systems 2019 of Illinois > 18 Installation Requirements for Seismic Protection > 18.4* Clearance
5.9.8.2 Special Application Elevators,
Requirement 2.8.3 does not apply. (a) All pipes shall be secured to prevent interference with the elevator equipment. (b) The clearance between ...
Safety Code for Elevators and Escalators 2019 of Illinois > 5 Special Application Elevators > 5.9 Mine Elevators > 5.9.8 Equipment in Hoistways, Machinery Spaces, Machine Rooms, Control Spaces, and Control Rooms > 5.9.8.2
(C) Wiring Methods and Materials, Clearance From Piping, Exposed Conductors, and So Forth
Conductors shall comply with 398.19 for clearances from other exposed conductors, piping, and so forth ...
National Electrical Code 2017 of Illinois > 3 Wiring Methods and Materials > 394 Concealed Knob-And-Tube Wiring > 394.19 Clearances > (C) Clearance From Piping, Exposed Conductors, and So Forth