1809.2.1 Pile Driving Hammer
JUMP TO FULL CODE CHAPTER
The hammer to be used to drive piles shall deliver a maximum energy consistent with the size, strength and weight of the driven piles. The pile-driving hammer shall travel freely in the leads. The hammer shall deliver its rated energy, and measurements shall be made of the fall of the ram or other suitable data shall be obtained at intervals necessary to verify the actual energy delivered during the final 20 blows of the hammer.
Related Code Sections
1809.2.1 Soils and Foundations, Pile Driving Hammer
The hammer to be used to drive piles shall deliver a maximum energy consistent with the size, strength and weight of the driven piles. The pile ...
NYC Building Code 2014 > 18 Soils and Foundations > 1809 Driven Piles > 1809.2 Equipment > 1809.2.1 Pile Driving Hammer
1808.2.17.2 Soils and Foundations, Equipment
be maintained in good working order. The pile-driving hammer shall travel freely in the leads. The hammer shall deliver its rated energy ...
NYC Building Code 2008 > 18 Soils and Foundations > 1808 Pier and Pile Foundations > 1808.2 Piers and Piles—General Requirements > 1808.2.17 Protection of Pile Materials > 1808.2.17.2 Equipment
1808.2.8.1.5.3 Soils and Foundations, Piles Installed by Use of Vibratory Hammer
:
Comparison piles, as required by the provisions of Item 4 below, shall be installed using an impact hammer and driving resistances ...
NYC Building Code 2008 > 18 Soils and Foundations > 1808 Pier and Pile Foundations > 1808.2 Piers and Piles—General Requirements > 1808.2.8 Allowable Pier or Pile Loads > 1808.2.8.1 Determination of Allowable Loads > 1808.2.8.1.5 Capacity as Indicated by Resistance to Penetration > 1808.2.8.1.5.3 Piles Installed by Use of Vibratory Hammer
§27-690 Foundations, Use of Existing Piles at Demolished Structures
, including load or hammer testing of representative piles, can be produced indicating the capacity, length, and driving conditions of the piles. The load ...
NYC 1968 Code (Vol I) > 11 Foundations > 7 Pile Foundations-General Requirements > §27-690 Use of Existing Piles at Demolished Structures
1809.4.3 Soils and Foundations, Use of Vibratory Drivers
Vibratory drivers shall only be used to install piles where the pile is subsequently seated by an impact hammer to the final driving criteria ...
NYC Building Code 2014 > 18 Soils and Foundations > 1809 Driven Piles > 1809.4 Installation of Driven Piles > 1809.4.3 Use of Vibratory Drivers