// CODE SNIPPET
Section 245 Picnic Facilities
JUMP TO FULL CODE CHAPTER
Picnic facilities, other than picnic facilities on trails, shall comply with 245.
Picnic facilities shall provide picnic units with mobility features in accordance with 245.2.
Where picnic facilities contain two or fewer picnic units, each picnic unit shall provide mobility features complying with 245.2.
Where picnic facilities contain more than two picnic units, at least 20 percent, but not less than two, of the picnic units shall provide mobility features complying with 245.2.
Where picnic units are altered or added, the requirements of 245.2 shall apply only to the picnic units that are altered or added until the number of picnic units with mobility features complies with the minimum number required in 245.2.1 or 245.2.2.
EXCEPTION: Where an entity is implementing a transition plan for program accessibility developed pursuant to regulations issued under section 504 of the Rehabilitation Act that designates specific picnic units to provide mobility features complying with 245.2, the entity shall not be required to comply with 245.2 when altering individual elements within picnic units that are not designated to provide mobility features complying with 245.2.
Picnic units required to provide mobility features complying with 245.2 shall provide choices of picnic units comparable to, and integrated with, those available to others.
Elements within picnic units required to provide mobility features shall comply with 245.2.5.
Where provided in common use and public use areas that serve picnic units with mobility features, at least 20 percent, but not less than one, of each type of outdoor constructed feature provided at each location shall comply with 1011.
Picnic facilities shall provide outdoor recreation access routes complying with 1016 in accordance with 245.4.
At least one outdoor recreation access route shall connect accessible elements, spaces, and facilities provided within picnic units with mobility features.
Common use and public use areas serving picnic units with mobility features shall provide outdoor recreation access routes in accordance with 245.4.2.
At least one outdoor recreation access route shall connect each picnic unit with mobility features with common use and public use areas serving that unit.
At least one outdoor recreation access route shall connect accessible elements, spaces, and facilities provided within common use and public use areas serving picnic units with mobility features.
Where a circulation path connects picnic facilities and adjacent recreation facilities, at least one outdoor recreation access route shall connect picnic units with mobility features to an accessible route serving the adjacent recreation facilities.
Related Code Sections
Section 245 Scoping Requirements, Picnic Facilities
Picnic facilities, other than picnic facilities on trails, shall comply with 245 ...
247.4.2 Scoping Requirements, Picnic Facilities
Picnic facilities provided on trails shall comply with 245.2 and 245.3 ...
2018 Illinois Accessibility Code > 2 Scoping Requirements > 247 Trails > 247.4 Trail Facilities > 247.4.2 Picnic Facilities
245.2.2 Scoping Requirements, Picnic Facilities With More Than Two Picnic Units
Where picnic facilities contain more than two picnic units, at least 20 percent, but not less than two, of the picnic units shall provide mobility ...
2018 Illinois Accessibility Code > 2 Scoping Requirements > 245 Picnic Facilities > 245.2 Picnic Units With Mobility Features > 245.2.2 Picnic Facilities With More Than Two Picnic Units
245.2.3 Scoping Requirements, Alterations and Additions
Where picnic units are altered or added, the requirements of 245.2 shall apply only to the picnic units that are altered or added until the number ...
2018 Illinois Accessibility Code > 2 Scoping Requirements > 245 Picnic Facilities > 245.2 Picnic Units With Mobility Features > 245.2.3 Alterations and Additions
245.2.4 Scoping Requirements, Dispersion
Picnic units required to provide mobility features complying with 245.2 shall provide choices of picnic units comparable to, and integrated ...
2018 Illinois Accessibility Code > 2 Scoping Requirements > 245 Picnic Facilities > 245.2 Picnic Units With Mobility Features > 245.2.4 Dispersion