1607.13.5.2 Photovoltaic Panels or Modules
JUMP TO FULL CODE CHAPTER
The structure of a roof that supports solar photovoltaic panels or modules shall be designed to accommodate the full solar photovoltaic panels or modules and ballast dead load, including concentrated loads from support frames in combination with the loads from Section 1607.13.5.1 and other applicable loads. Where applicable, snow drift loads created by the photovoltaic panels or modules shall be included.
Structures with open grid framing and without a roof deck or sheathing supporting photovoltaic panel systems shall be designed to support the uniform and concentrated roof live loads specified in Section 1607.13.5.1, except that the uniform roof live load shall be permitted to be reduced to 12 psf (0.57 kN/m2).
Related Code Sections
1510.7 Roof Assemblies and Rooftop Structures, Photovoltaic Panels and Modules
Rooftop-mounted photovoltaic panels and modules shall be designed in accordance with this section ...
Building Code 2018 of New Jersey > 15 Roof Assemblies and Rooftop Structures > 1510 Rooftop Structures > 1510.7 Photovoltaic Panels and Modules
Section 1512 Roof Assemblies and Rooftop Structures, Photovoltaic Panels and Modules
Photovoltaic panels and modules installed upon a roof or as an integral part of a roof assembly shall comply with the requirements of this code ...
Building Code 2015 of New Jersey > 15 Roof Assemblies and Rooftop Structures > 1512 Photovoltaic Panels and Modules
Section 1512 Roof Assemblies and Rooftop Structures, Photovoltaic Panels and Modules
Photovoltaic panels and modules installed on a roof or as an integral part of a roof assembly shall comply with the requirements of this code ...
Building Code 2018 of New Jersey > 15 Roof Assemblies and Rooftop Structures > 1512 Photovoltaic Panels and Modules
1607.12.5.2 Structural Design, Photovoltaic Panels or Modules
The structure of a roof that supports solar photovoltaic panels or modules shall be designed to accommodate the full solar photovoltaic panels ...
Building Code 2015 of New Jersey > 16 Structural Design > 1607 Live Loads > 1607.12 Roof Loads > 1607.12.5 Photovoltaic Panel Systems > 1607.12.5.2 Photovoltaic Panels or Modules