• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.1427(k) Phase-In

OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1427 Operator Qualification and Certification > 1926.1427(k) Phase-In
JUMP TO FULL CODE CHAPTER

1926.1427(k)(1)

The provisions of this section became applicable on November 8, 2010, except for paragraphs (a)(2) and (f) of this section, which are applicable November 10, 2018.

1926.1427(k)(2)

When paragraph (a)(1) of this section is not applicable, all of the requirements in paragraphs (k)(2)(i) and (ii) of this section apply until November 10, 2018.

1926.1427(k)(2)(i)

The employer must ensure that operators of equipment covered by this standard are competent to operate the equipment safely.

1926.1427(k)(2)(ii)

When an employee assigned to operate machinery does not have the required knowledge or ability to operate the equipment safely, the employer must train that employee prior to operating the equipment. The employer must ensure that each operator is evaluated to confirm that he/she understands the information provided in the training.

[75 FR 48156, August 9, 2010; 79 FR 57798, September 26, 2014; 82 FR 51998, November 9, 2017]

Related Code Sections


1926.1427(k) Cranes & Derricks in Construction, Phase-In
The provisions of this section became applicable on November 8, 2010, except for paragraphs (a)(2) and (f) of this section, which are applicable ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1427 Operator Qualification and Certification > 1926.1427(k) Phase-In
1926.960(c)(1)(i) Electric Power Transmission and Distribution,
TABLE V-3-ELECTRICAL COMPONENT OF THE MINIMUM APPROACH DISTANCE (D; IN METERS) AT 5.1 TO 72.5 KV Nominal voltage (kV) phase-to-phase ...
OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.960 Working on or Near Exposed Energized Parts > 1926.960(c) Live Work > 1926.960(c)(1) Minimum Approach Distances > 1926.960(c)(1)(i)
1926.960(c) Electric Power Transmission and Distribution, Live Work
TABLE V-3-ELECTRICAL COMPONENT OF THE MINIMUM APPROACH DISTANCE (D; IN METERS) AT 5.1 TO 72.5 KV Nominal voltage (kV) phase-to-phase ...
OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.960 Working on or Near Exposed Energized Parts > 1926.960(c) Live Work
Subpart V Electric Power Transmission and Distribution, App B - Working on Exposed Energized Parts
Otherwise, C is 0.011. In Equation 1, the term a varies depending on whether the employee's exposure is phase-to-ground or phase-to-phase ...
OSHA 1926 Construction > V Electric Power Transmission and Distribution > V App B - Working on Exposed Energized Parts
1926.960 Electric Power Transmission and Distribution, Working on or Near Exposed Energized Parts
TABLE V-3-ELECTRICAL COMPONENT OF THE MINIMUM APPROACH DISTANCE (D; IN METERS) AT 5.1 TO 72.5 KV Nominal voltage (kV) phase-to-phase ...
OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.960 Working on or Near Exposed Energized Parts
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING