• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

505.7.1 Pharmacies - Laminar Flow Biological Safety Cabinet. [CA - Board of Pharmacy]

Los Angeles Mechanical Code > 5 Exhaust Systems > 505.0 Product-Conveying Systems > 505.7 Pharmacies - Compounding Area of Parenteral Solutions. [CA - Board of Pharmacy] > 505.7.1 Pharmacies - Laminar Flow Biological Safety Cabinet. [CA - Board of Pharmacy]
JUMP TO FULL CODE CHAPTER
In all pharmacies preparing parenteral cytotoxic agents, all compounding shall be conducted within a certified Class II Type A or Class II Type B vertical laminar airflow hood with bag in - bag out design. The pharmacy must ensure that contaminated air plenums that are under positive air pressure are leak tight.

Note: For additional pharmacy building standard requirements, see Chapter 12, California Building Code.

Related Code Sections


505.7.1 Exhaust Systems, Pharmacies - Laminar Flow Biological Safety Cabinet. [CA - Board of Pharmacy]
vertical laminar airflow hood with bag in - bag out design. The pharmacy must ensure that contaminated air plenums that are under positive air pressure ...
Los Angeles Mechanical Code > 5 Exhaust Systems > 505.0 Product-Conveying Systems > 505.7 Pharmacies - Compounding Area of Parenteral Solutions. [CA - Board of Pharmacy] > 505.7.1 Pharmacies - Laminar Flow Biological Safety Cabinet. [CA - Board of Pharmacy]
505.12.1 Exhaust Systems, Pharmacies-Laminar Flow Biological Safety Cabinet
[CA-Board of Pharmacy] In all pharmacies preparing parenteral cytotoxic agents, all compounding shall be conducted within a certified Class II Type ...
Los Angeles Mechanical Code > 5 Exhaust Systems > 505.0 Product-Conveying Systems > 505.12 Pharmacies-Compounding Area of Parenteral Solutions > 505.12.1 Pharmacies-Laminar Flow Biological Safety Cabinet
Section 1250 Interior Environment, [CA] Pharmacies
tiles, walls, floors and floor coverings. The pharmacy shall be arranged in such a manner that the laminar-flow hood is located in an area which ...
Los Angeles Building Code > 12 Interior Environment > 1250 [CA] Pharmacies
1225.5.1.3.5 Interior Environment, Pharmacy
The pharmacy shall not serve the general public unless a separate public entrance or a separate public serving window is utilized ...
Los Angeles Building Code > 12 Interior Environment > 1225 [OSHPD 2] Skilled Nursing and Intermediate-Care Facilities > 1225.5 Skilled Nursing Unit Models > 1225.5.1 Medical Model > 1225.5.1.3 Pharmaceutical Service Space > 1225.5.1.3.5 Pharmacy
1224.19.1 Interior Environment, Licensed Pharmacy
All hospitals having a licensed capacity of 100 or more beds shall have a pharmacy on the premises licensed by the California Board of Pharmacy ...
Los Angeles Building Code > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.19 Pharmaceutical Service Space > 1224.19.1 Licensed Pharmacy
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE