1926.1431(f) Personnel Platform Loading
JUMP TO FULL CODE CHAPTER
The personnel platform must not be loaded in excess of its rated capacity.
Personnel platforms must be used only for employees, their tools, and the materials necessary to do their work. Platforms must not be used to hoist materials or tools when not hoisting personnel.
Materials and tools to be used during the lift, if secured and distributed in accordance with paragraph (f)(3) of this section may be in the platform for trial lifts.
Evenly distributed within the confines of the platform while it is suspended.
The number of employees occupying the personnel platform must not exceed the maximum number the platform was designed to hold or the number required to perform the work, whichever is less.
Related Code Sections
1926.1431(f) Cranes & Derricks in Construction, Personnel Platform Loading
The personnel platform must not be loaded in excess of its rated capacity ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(f) Personnel Platform Loading
1926.1431(f)(2)(ii) Cranes & Derricks in Construction, Exception
Materials and tools to be used during the lift, if secured and distributed in accordance with paragraph (f)(3) of this section may be in the platform ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(f) Personnel Platform Loading > 1926.1431(f)(2) Use > 1926.1431(f)(2)(ii) Exception
1926.1431(f)(3)(ii) Cranes & Derricks in Construction,
Evenly distributed within the confines of the platform while it is suspended ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(f) Personnel Platform Loading > 1926.1431(f)(3) Materials and Tools Must Be: > 1926.1431(f)(3)(ii)
1926.1431(f)(3)(i) Cranes & Derricks in Construction, Secured to Prevent Displacement
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(f) Personnel Platform Loading > 1926.1431(f)(3) Materials and Tools Must Be: > 1926.1431(f)(3)(i) Secured to Prevent Displacement
1926.1431(h)(1) Cranes & Derricks in Construction,
A trial lift with the unoccupied personnel platform loaded at least to the anticipated liftweight must be made from ground level, or any other ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(h) Trial Lift and Inspection > 1926.1431(h)(1)