3004.4 Personnel and Material Hoists
JUMP TO FULL CODE CHAPTER
Personnel and material hoists shall be designed utilizing an approved method that accounts for the conditions imposed during the intended operation of the hoist device. The design shall include, but is not limited to, anticipated loads, structural stability, impact, vibration, stresses and seismic restraint. The design shall account for the construction, installation, operation and inspection of the hoist tower, car, machinery and control equipment, guide members and hoisting mechanism. Additionally, the design of personnel hoists shall include provisions for field testing and maintenance that will demonstrate that the hoist device functions in accordance with the design. Field tests shall be conducted upon the completion of an installation or following a major alteration of a personnel hoist.
Related Code Sections
3004.4 Elevators and Conveying Systems, Personnel and Material Hoists
Personnel and material hoists shall be designed utilizing an approved method that accounts for the conditions imposed during the intended operation ...
Building Code 2021 of Illinois > 30 Elevators and Conveying Systems > 3004 Conveying Systems > 3004.4 Personnel and Material Hoists
3004.4 Elevators and Conveying Systems, Personnel and Material Hoists
Personnel and material hoists shall be designed utilizing an approved method that accounts for the conditions imposed during the intended operation ...
Building Code 2018 of Illinois > 30 Elevators and Conveying Systems > 3004 Conveying Systems > 3004.4 Personnel and Material Hoists
203.2 Scoping Requirements, Construction Sites
hoists, materials storage, and construction trailers shall not be required to comply with these requirements or to be on an accessible route. Portable ...
2018 Illinois Accessibility Code > 2 Scoping Requirements > 203 General Exceptions > 203.2 Construction Sites
555.9 Special Occupancies, Boat Hoists
GFCI protection for personnel shall be provided for outlets not exceeding 240 volts that supply a boat hoist installed at dwelling unit docking ...
National Electrical Code 2020 of Illinois > 5 Special Occupancies > 555 Marinas, Boatyards, Floating Buildings, and Commercial and Noncommercial Docking Facilities > 555.9 Boat Hoists
(C) Wiring and Protection, Boat Hoists
GFCI protection shall be provided for outlets not exceeding 240 volts that supply boat hoists installed in dwelling unit locations ...
National Electrical Code 2017 of Illinois > 2 Wiring and Protection > 210 Branch Circuits > 210.8 Ground-Fault Circuit-Interrupter Protection for Personnel > (C) Boat Hoists