• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.268(g) Personal Climbing Equipment

OSHA 1910 General Industry > R Special Industries > 1910.268 Telecommunications > 1910.268(g) Personal Climbing Equipment
JUMP TO FULL CODE CHAPTER
—

1910.268(g)(1) General

A positioning system or a personal fall arrest system shall be provided and the employer shall ensure their use when work is performed at positions more than 4 feet (1.2 m) above the ground, on poles, and on towers, except as provided in paragraphs (n)(7) and (8) of this section. These systems shall meet the applicable requirements in subpart I of this part. The employer shall ensure that all climbing equipment is inspected before each day's use to determine that it is in safe working condition.

1910.268(g)(2) Pole Climbers

1910.268(g)(2)(i)

Pole climbers may not be used if the gaffs are less than 1 1/4 inches in length as measured on the underside of the gaff. The gaffs of pole climbers shall be covered with safety caps when not being used for their intended use.

1910.268(g)(2)(iii)

Pole climbers shall be inspected as required in this paragraph (g)(3) before each day's use and a gaff cut-out test performed at least weekly when in use.

1910.268(g)(2)(iv)

Pole climbers may not be worn when:

1910.268(g)(2)(iv)(A)

Working in trees (specifically designed tree climbers shall be used for tree climbing),

1910.268(g)(2)(iv)(B)

Working on ladders,

1910.268(g)(2)(iv)(C)

Working in an aerial lift,

1910.268(g)(2)(iv)(D)

Driving a vehicle, nor

1910.268(g)(2)(iv)(E)

Walking on rocky, hard, frozen, brushy or hilly terrain.

1910.268(g)(2)(ii)

The employer shall ensure that pole climbers are inspected by a competent person for the following conditions: Fractured or cracked gaffs or leg irons, loose or dull gaffs, broken straps or buckles. If any of these conditions exist, the defect shall be corrected before the climbers are used.

Related Code Sections


1910.268(g) Special Industries, Personal Climbing Equipment
of this part. The employer shall ensure that all climbing equipment is inspected before each day's use to determine that it is in safe working ...
OSHA 1910 General Industry > R Special Industries > 1910.268 Telecommunications > 1910.268(g) Personal Climbing Equipment
1910.268(g)(2)(iii) Special Industries,
Pole climbers shall be inspected as required in this paragraph (g)(3) before each day's use and a gaff cut-out test performed at least weekly when ...
OSHA 1910 General Industry > R Special Industries > 1910.268 Telecommunications > 1910.268(g) Personal Climbing Equipment > 1910.268(g)(2) Pole Climbers > 1910.268(g)(2)(iii)
1910.268(g)(2)(iv) Special Industries,
in trees (specifically designed tree climbers shall be used for tree climbing ...
OSHA 1910 General Industry > R Special Industries > 1910.268 Telecommunications > 1910.268(g) Personal Climbing Equipment > 1910.268(g)(2) Pole Climbers > 1910.268(g)(2)(iv)
1910.268(g)(2)(iv)(B) Special Industries,
Working on ladders ...
OSHA 1910 General Industry > R Special Industries > 1910.268 Telecommunications > 1910.268(g) Personal Climbing Equipment > 1910.268(g)(2) Pole Climbers > 1910.268(g)(2)(iv) > 1910.268(g)(2)(iv)(B)
1910.268(g)(2)(iv)(C) Special Industries,
Working in an aerial lift ...
OSHA 1910 General Industry > R Special Industries > 1910.268 Telecommunications > 1910.268(g) Personal Climbing Equipment > 1910.268(g)(2) Pole Climbers > 1910.268(g)(2)(iv) > 1910.268(g)(2)(iv)(C)
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING