// CODE SNIPPET
23-621 Permitted Obstructions in Certain Districts
JUMP TO FULL CODE CHAPTER
R2A R2X R3 R4 R4-1 R4A R5A
(a) In the districts indicated, permitted obstructions are limited to chimneys, exterior wall thickness, flag poles or aerials, parapet walls, roof thickness, skylights, solar energy systems and vegetated roofs pursuant to Section 23-62. However, in R3-2 and R4 Districts, except R4-1, R4A and R4B Districts, elevator or stair bulkheads, roof water tanks and accessory mechanical equipment provided pursuant to paragraph (g) of Section 23-62 shall be permitted for buildings containing affordable independent residences for seniors.
(b) In R2X Districts, dormers may be considered permitted obstructions if:
(1) the aggregate width of dormers facing the street line is equal to not more than 50 percent of the width of the street wall line ;
(2) the aggregate width of dormers facing the rear lot line is equal to not more than 50 percent of the width of the rear wall line ;
(3) the aggregate width of dormers facing a side lot line is equal to not more than 50 percent of the width of a straight line connecting and perpendicular to the street wall line and the rear wall line ; and
(4) on a corner lot, the aggregate width of dormers facing a side lot line is equal to not more than 50 percent of the width of the rear wall line facing such side lot line.
R6 R7 R8 R9 R10
(c) In the districts indicated, for Quality Housing buildings, the permitted obstructions set forth in Section 23-62 shall apply to any building or other structure, except that within a required front setback distance above a maximum base height, the following rules shall apply:
(1) Dormers shall be allowed as a permitted obstruction, provided that on any street frontage, the aggregate width of all dormers at the maximum base height does not exceed 60 percent of the width of the street wall of the highest story entirely below the maximum base height. For each foot above the maximum base height, the aggregate width of all dormers shall be decreased by one percent of the street wall width of the highest story entirely below the maximum base height.

Dormer
(23-621c, 62-341d.2)
(2) Solar energy systems on a roof shall be limited to four feet or less in height, as measured from the maximum height limit, or the finished level of the roof, whichever is higher. However, on a roof with a slope greater than 20 degrees, such systems shall be limited to 18 inches in height as measured perpendicular to the roof surface.
(3) Wind energy systems shall not be allowed as permitted obstructions.
(4) Window washing equipment shall not be allowed as permitted obstructions.
Related Code Sections
§28-212.1 Enforcement, Abatement of Public Nuisances Caused by Illegal Commercial or Manufacturing Occupancy in Residence Districts and Certain Other Zoning Districts
Any building or part thereof or vacant land that is located in a residence zoning district and that is occupied for a use not permitted ...
NYC General Admin. Provisions 2008 > 2 Enforcement > 212 Abatement of Public Nuisance Caused by Certain Illegal Occupancies > §28-212.1 Abatement of Public Nuisances Caused by Illegal Commercial or Manufacturing Occupancy in Residence Districts and Certain Other Zoning Districts
§28-212.1 Enforcement, Abatement of Public Nuisances Caused by Illegal Commercial or Manufacturing Occupancy in Residence Districts and Certain Other Zoning Districts
Any building or part thereof or vacant land that is located in a residence zoning district and that is occupied for a use not permitted ...
NYC General Admin. Provisions 2014 > 2 Enforcement > 212 Abatement of Public Nuisance Caused by Certain Illegal Occupancies > §28-212.1 Abatement of Public Nuisances Caused by Illegal Commercial or Manufacturing Occupancy in Residence Districts and Certain Other Zoning Districts
§28-212.1 Enforcement, Abatement of Public Nuisances Caused by Illegal Commercial or Manufacturing Occupancy in Residence Districts and Certain Other Zoning Districts
Any building or part thereof or vacant land that is located in a residence zoning district and that is occupied for a use not permitted ...
NYC General Admin. Provisions 2022 > 2 Enforcement > 212 Abatement of Public Nuisance Caused by Certain Illegal Occupancies > §28-212.1 Abatement of Public Nuisances Caused by Illegal Commercial or Manufacturing Occupancy in Residence Districts and Certain Other Zoning Districts
§28-104.7.12 Administration, Waiver of Certain Documents
is not necessary to ascertain compliance with this code or not required for the phase of work for which a permit is sought ...
NYC General Admin. Provisions 2008 > 1 Administration > 104 Construction Documents > §28-104.7 Submittal of Construction Documents > §28-104.7.12 Waiver of Certain Documents
§28-104.7.12 Administration, Waiver of Certain Documents
is not necessary to ascertain compliance with this code or not required for the phase of work for which a permit is sought ...
NYC General Admin. Provisions 2014 > 1 Administration > 104 Construction Documents > §28-104.7 Submittal of Construction Documents > §28-104.7.12 Waiver of Certain Documents