• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

64-331 Permitted Obstructions for Multi-Family Buildings in R3-2 and R4 Districts

NYC Zoning Resolution > VI Special Regulations Applicable to Certain Areas > 4 - Special Regulations Applying in Flood Hazard Areas > 64-30 Special Bulk Regulations > 64-33 Special Height and Setback Regulations > 64-331 Permitted Obstructions for Multi-Family Buildings in R3-2 and R4 Districts
JUMP TO FULL CODE CHAPTER
The provisions of this Section shall apply without requiring a building to comply with flood-resistant construction standards as established in paragraph (a) of Section 64-12 (Applicability).
In R3-2 and R4 Districts, for all buildings, or portions thereof, subject to Section 23-60 (HEIGHT AND SETBACK REGULATIONS), except single- and two-family residences, elevator or stair bulkheads (including shafts, and vestibules not larger than 60 square feet in area providing access to a roof), roof water tanks and accessory mechanical equipment (including enclosures), other than solar or wind energy systems, shall be considered permitted obstructions to height and setback regulations, provided that:
(a)        such obstructions shall be located not less than 10 feet from the street wall of a building;
(b)        all mechanical equipment shall be screened on all sides;
(c)        the lot coverage of all such obstructions and screening does not exceed 250 square feet or 10 percent of the lot coverage of the building, whichever is greater; and
(d)        such obstructions are limited to a height of 15 feet above the maximum height of perimeter walls.

Related Code Sections


D105.1 Fire Districts, General
Existing one- and two-family dwellings of a type of construction not permitted in the fire district can be extended 25 percent of the floor area ...
NYC Building Code 2008 > D Fire Districts > D105 Exceptions to Restrictions in Fire District > D105.1 General
D105.1 Fire Districts, General
Existing one- and two-family dwellings of a type of construction not permitted in the fire district can be extended 25 percent of the floor area ...
NYC Building Code 2014 > D Fire Districts > D105 Exceptions to Restrictions in Fire District > D105.1 General
D105.1 Fire Districts, General
Existing one- and two-family dwellings of a type of construction not permitted in the fire district can be extended 25 percent of the floor area ...
NYC Building Code 2022 > D Fire Districts > D105 Exceptions to Restrictions in Fire District > D105.1 General
Article 4 Building Limitations, Limitations Inside the Fire Districts
No buildings in those combinations of construction classes and occupancy groups prohibited by tables 4-1 and 4-2 shall be erected inside the fire ...
NYC 1968 Code (Vol I) > 4 Building Limitations > 4 Limitations Inside the Fire Districts
1305.15.1 Fuel-Oil Piping and Storage, Use
Nonmetallic tanks shall be permitted for one- and two-family dwellings only. Use of nonmetallic tanks in multi-family dwellings is prohibited ...
NYC Mechanical Code 2022 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.15 Above-Ground Nonmetallic Fuel-Oil Storage Tanks for One- And Two-Family Dwellings > 1305.15.1 Use
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING