64-432 Permitted Obstructions for Certain Existing Buildings
JUMP TO FULL CODE CHAPTER
The provisions of this Section shall apply without requiring a building to comply with flood-resistant construction standards as established in paragraph (a) of Section 64-12 (Applicability).
In R5 through R10 Districts, and in Commercial and Manufacturing Districts, for all existing buildings, the regulations for permitted obstructions to height and setback regulations shall be modified to increase the permitted volume for elevator or stair bulkheads (including shafts, and vestibules not larger than 60 square feet in area providing access to a roof), roof water tanks and accessory mechanical equipment (including enclosures), other than solar or wind energy systems, as follows:
(a) where the maximum building height is less than 120 feet, the maximum permitted height of such volume may be increased from 25 feet to 33 feet, provided that the lot coverage of all such obstructions does not exceed 20 percent of the lot coverage of the building; and
(b) where the maximum building height is 120 feet or greater, the maximum permitted height of such volume may be increased from 40 feet to 55 feet, provided that the lot coverage of all such obstructions does not exceed 20 percent of the lot coverage of the building.
Related Code Sections
501.3.2.3 General Building Heights and Areas; Separation of Occupancies, Signs Obstructing Openings
Where wall signs are erected to cover doors or windows of existing buildings, access panels shall be provided as necessary to comply ...
NYC Building Code 2008 > 5 General Building Heights and Areas; Separation of Occupancies > 501 General > 501.3 Fire Department Access > 501.3.2 Building Access > 501.3.2.3 Signs Obstructing Openings
G304.4.1 Flood-Resistant Construction, Alterations to Certain Flood Design Class 4 Buildings
Where an existing emergency vehicle garage or fire,
rescue, ambulance, or police station building ...
NYC Building Code 2022 > G Flood-Resistant Construction > G304 Post-Firm Construction, Horizontal Enlargements and Substantial Improvements > G304.4 Construction Standards for Shaded X-Zones > G304.4.1 Alterations to Certain Flood Design Class 4 Buildings
903.2.11.4 Fire Protection Systems, Signs Obstructing Openings
Where wall signs are erected to cover doors or windows of existing buildings, access panels shall be provided as necessary to comply ...
NYC Building Code 2014 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.11 Specific Building Areas and Hazards > 903.2.11.4 Signs Obstructing Openings
903.2.11.4 Fire Protection Systems, Signs Obstructing Openings
Where wall signs are erected to cover doors or windows of existing buildings, access panels shall be provided as necessary to comply ...
NYC Building Code 2022 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.11 Specific Building Areas and Hazards > 903.2.11.4 Signs Obstructing Openings
*§28-105.1.2 Administration, Denial of Permits for Certain Arrears
The commissioner shall not issue a permit for a new building, demolition, place of assembly or major alteration that will change ...
NYC General Admin. Provisions 2014 > 1 Administration > 105 Permits > §28-105.1 General > *§28-105.1.2 Denial of Permits for Certain Arrears