64-332 Permitted Obstructions for Buildings in Medium and High Density Districts
JUMP TO FULL CODE CHAPTER
The provisions of this Section shall apply without requiring a building to comply with flood-resistant construction standards as established in paragraph (a) of Section 64-12 (Applicability).
In R5 through R10 Districts, and in all Commercial and Manufacturing Districts, for all buildings, the underlying regulations governing permitted obstructions to height and setback shall be modified to increase the permitted volume for elevator or stair bulkheads (including shafts, and vestibules not larger than 60 square feet in area providing access to a roof), roof water tanks and accessory mechanical equipment (including enclosures), other than solar or wind energy systems, from a maximum lot coverage of 20 percent of the lot coverage of the building to a maximum lot coverage of 30 percent of the lot coverage of the building, provided that where the maximum permitted height of a building is less than 120 feet, such obstructions are limited to a maximum height of 25 feet, and where the maximum permitted height of a building is 120 feet or greater, such obstructions are limited to a maximum height of 40 feet.
Related Code Sections
D105.1 Fire Districts, General
Existing one- and two-family dwellings of a type of construction not permitted in the fire district can be extended 25 percent of the floor area ...
NYC Building Code 2014 > D Fire Districts > D105 Exceptions to Restrictions in Fire District > D105.1 General
D105.1 Fire Districts, General
Existing one- and two-family dwellings of a type of construction not permitted in the fire district can be extended 25 percent of the floor area ...
NYC Building Code 2022 > D Fire Districts > D105 Exceptions to Restrictions in Fire District > D105.1 General
308.3.2 Building Blocks, Obstructed High Reach
Where a clear floor space complying with Section 305 allows a parallel approach to an element and the high side reach is over an obstruction ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 3 Building Blocks > 308 Reach Ranges > 308.3 Side Reach > 308.3.2 Obstructed High Reach
D105.1 Fire Districts, General
Existing one- and two-family dwellings of a type of construction not permitted in the fire district can be extended 25 percent of the floor area ...
NYC Building Code 2008 > D Fire Districts > D105 Exceptions to Restrictions in Fire District > D105.1 General
2113.11.2 Masonry, Masonry Chimneys for Medium-Heat Appliances
, penthouse, or other obstruction within 50 feet (15 240 mm) of the chimney outlet, whether the construction is on the same building as the chimney ...
NYC Building Code 2022 > 21 Masonry > 2113 Masonry Chimneys > 2113.11 Flue Lining (Material) > 2113.11.2 Masonry Chimneys for Medium-Heat Appliances