• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1312.1 Permitted Locations for Medical Gas

Uniform Plumbing Code 2018 of Nevada > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1312.0 Central Supply Systems > 1312.1 Permitted Locations for Medical Gas
JUMP TO FULL CODE CHAPTER
Central supply systems and medical gas outlets for oxygen, medical air, nitrous oxide, carbon dioxide, and all other patient medical gases shall be piped only into areas where the gases will be used under the direction of licensed medical professionals for purposes congruent with the following:
  1. Direct respiration by patients.
  2. Clinical application of the gas to a patient, such as the use of an insufflator to inject carbon dioxide into patient body cavities during laparoscopic surgery and carbon dioxide used to purge heart-lung machine blood flow ways.
  3. Medical device applications directly related to respiration.
  4. Power for medical devices used directly on patients.
  5. Calibration of medical devices intended for Section 1312.1(1) through Section 1312.1(4). [NFPA 99:5.1.3.5.2]

Related Code Sections


1312.1 Health Care Facilities and Medical Gas and Medical Vacuum Systems, Permitted Locations for Medical Gas
Central supply systems and medical gas outlets for oxygen, medical air, nitrous oxide, carbon dioxide, and all other patient medical gases shall ...
Uniform Plumbing Code 2018 of Nevada > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1312.0 Central Supply Systems > 1312.1 Permitted Locations for Medical Gas
1310.4 Health Care Facilities and Medical Gas and Medical Vacuum Systems, Location of Piping
] Medical gas piping shall not be located where ...
Uniform Plumbing Code 2018 of Nevada > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1310.0 Installation of Piping > 1310.4 Location of Piping
1304.0 Health Care Facilities and Medical Gas and Medical Vacuum Systems, Medical Gas and Medical Vacuum Piping Systems
The installation of medical gas and medical vacuum piping systems shall comply with the requirements of this chapter ...
Uniform Plumbing Code 2018 of Nevada > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1304.0 Medical Gas and Medical Vacuum Piping Systems
Section 427 Special Detailed Requirements Based on Occupancy and Use, Medical Gas Systems
Medical gases shall be located in areas dedicated to the storage of such gases without other storage or uses. Where containers of medical ...
Building Code 2018 of Nevada > 4 Special Detailed Requirements Based on Occupancy and Use > 427 Medical Gas Systems
1313.2 Health Care Facilities and Medical Gas and Medical Vacuum Systems, Medical Air Compressors
with drainage facilities in accordance with this code. The medical air compressor area shall be located separately from medical gas cylinder system ...
Uniform Plumbing Code 2018 of Nevada > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1313.0 Medical Air Supply Systems > 1313.2 Medical Air Compressors
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING