Section P-411 Permitted Joints
JUMP TO FULL CODE CHAPTER
The types of joints permitted above ground inside of a building are:
- Cast iron hub stack to plastic with plastic to soil adapter;
- Cast iron hub stack to copper with adapter, lead and oakum joint;
- Cast iron hub stack to steel pipe, lead and oakum joint;
- Cast iron no-hub stack to plastic or copper with no-hub coupling;
- PVC connected to ABS with male and female adapters.
- No-hub coupling shall be permitted for ABS connected to PVC.
For repair of underground storm, sanitary or combined main drain lines, a double hub cast
iron fitting shall be permitted with the approval of the Department. Such joints shall be properly caulked and
supported.
In replacing a broken house trap, an approved mechanical type fitting shall be permitted on one
side of the trap.
Under severe conditions, two fittings shall be permitted, with approval of the Department.
The use of two fittings shall require concrete encasement on the street side.
Related Code Sections
Section P-411 Joints, Permitted Joints
The types of joints permitted above ground inside of a building are:
Cast iron hub stack to plastic with plastic to soil adapter;
Cast iron ...
P-305.5 Materials, Pipes and Joints Permitted
Pipe and joint material shall be in accordance with Table P-305.5.
Table P-305.5 — APPROVED PIPES AND TYPES OF JOINTS
Pipes/Joints ...
Philadelphia Plumbing Code > 3 Materials > P-305 Materials for Plumbing Installations > P-305.5 Pipes and Joints Permitted
712.1.5 Fire and Smoke Protection Features, Joints
Joints shall be permitted where complying with Section 712.1.5.1 or 712.1.5.2, as applicable ...
Philadelphia Building Code > 7 Fire and Smoke Protection Features > 712 Vertical Openings > 712.1 General > 712.1.5 Joints
6.5.4* System Components and Hardware, Brazed and Soldered Joints
Solder joints, where permitted, shall be fabricated in accordance with the methods and procedures listed in ASTM B828, Standard Practice for Making ...
Standard for the Installation of Sprinkler Systems 2016 of Philadelphia > 6 System Components and Hardware > 6.5 Joining of Pipe and Fittings > 6.5.4* Brazed and Soldered Joints
605.18.1 Water Supply and Distribution, Flared Joints
Flared joints shall be permitted where so indicated by the pipe manufacturer. Flared joints shall be made by a tool designed for that operation ...
Plumbing Code 2018 of Philadelphia > 6 Water Supply and Distribution > 605 Materials, Joints and Connections > 605.18 PE Plastic > 605.18.1 Flared Joints