104-73 Permitted Curb Cut Locations
JUMP TO FULL CODE CHAPTER
The following curb cut regulations shall apply to any development or enlargement:
(a) existing curb cuts on wide streets may remain until such time as a community facility use is located on that portion of the zoning lot;
(b) no new curb cuts are permitted on wide streets or within 50 feet of the intersection of any two street lines. Furthermore, no curb cuts are permitted on Block B. However, curb cuts may be permitted in such areas where the Commissioner of Buildings determines there is no alternative means of access to off-street parking spaces or required loading berths from other streets bounding the block or zoning lot;
(c) new curb cuts shall not be greater than 30 feet in width;
(d) there shall be no more than two new curb cuts per street frontage on a zoning lot, except on Block F where three curb cuts per street frontage are permitted, and except as provided in paragraph (f) of this Section;
(e) there shall be a minimum distance of 30 feet between curb cuts on a street frontage of a zoning lot; and
(f) in order to access the Square, as described in Section 104-424, one curb cut, not to exceed 15 feet in width, shall be permitted along each street frontage of the sidewalk adjacent to the Square. Such curb cuts shall be in addition to the two curb cuts permitted on Block D, pursuant to paragraph (d) of this Section.
Related Code Sections
406.7.6 Special Detailed Requirements Based on Use and Occupancy, Curb Cuts
mm) in length may be permitted. No curb cut shall commence within 8 feet (2438 mm) of a side lot line, except that on corner lots and lots ...
NYC Building Code 2014 > 4 Special Detailed Requirements Based on Use and Occupancy > 406 Motor-Vehicle-Related Occupancies > 406.7 Open Parking Lots > 406.7.6 Curb Cuts
406.7.6 Special Detailed Requirements Based on Use and Occupancy, Curb Cuts
no greater than 30 feet (9144 mm) in length may be permitted. 3. No curb cut shall commence within 8 feet (2438 mm) of a side lot line ...
NYC Building Code 2008 > 4 Special Detailed Requirements Based on Use and Occupancy > 406 Motor Vehicle-Related Occupancies > 406.7 Open Parking Lots > 406.7.6 Curb Cuts
406.10 Special Detailed Requirements Based on Use and Occupancy, Curb Cuts and Driveways
feet (30 480 mm), an
additional curb cut no greater than 30 feet (9144 mm) in length may be permitted.
No curb cut shall commence within 8 feet ...
NYC Building Code 2022 > 4 Special Detailed Requirements Based on Use and Occupancy > 406 Motor-Vehicle-Related Occupancies > 406.10 Curb Cuts and Driveways
3202.2.2.4 Encroachments Into the Public Right-Of-Way, Curb Cuts
Vehicular access curb cuts that can no longer serve as vehicular access across a curb or sidewalk shall be removed and the curb ...
NYC Building Code 2014 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.2 Encroachments Above Grade > 3202.2.2 Encroachments Not Subject to Area Limitations > 3202.2.2.4 Curb Cuts
3202.2.2.4 Encroachments Into the Public Right-Of-Way, Curb Cuts
Vehicular access curb cuts that can no longer serve as vehicular access across a curb or sidewalk, including where an existing ...
NYC Building Code 2022 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.2 Encroachments Above Grade > 3202.2.2 Encroachments Not Subject to Area Limitations > 3202.2.2.4 Curb Cuts