• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3309.5.4 Permit Holder Responsibilities

NYC Fire Code 2014 > 33 Explosives, Fireworks and Special Effects > 3309 Special Effects > 3309.5 Production Company Special Effects Permit > 3309.5.4 Permit Holder Responsibilities
JUMP TO FULL CODE CHAPTER
A production company special effects permit holder shall be responsible for the safe conduct of the special effects and the safe storage and handling of all materials, articles or devices used therefore, in the manner prescribed by the commissioner, including:
  1. The construction and maintenance of a central storage facility in compliance with all applicable federal, state and local laws, rules and regulations, including all permit and fire protection requirements, and ensuring adequate security of such facility.
  2. Ensuring compliance with all applicable laws, rules and regulations, including the federal, state and local laws, rules and regulations governing the transportation of all pyrotechnic materials, articles and devices and all other materials, articles or devices of an explosive, flammable, or combustible nature, and the permit, labeling and fire protection requirements thereof.
  3. Ensuring that all special effects are conducted by a person holding a certificate of fitness for special effects, and all materials, articles or devices for such purpose are handled and stored by or under the supervision of such a person, as required by this section.
  4. Ensuring compliance with the directions of department representatives.
  5. Obtaining a liability and casualty insurance policy as set forth in FC3301.2.4(4).

Related Code Sections


1704.1.1.3 Special Inspections and Tests, Responsibilities of the Permit Holder
The permit holder shall have the following duties and responsibilities: Statement of special inspections. The application for permit shall ...
NYC Building Code 2022 > 17 Special Inspections and Tests > 1704 Responsibilities for Special Inspections and Tests > 1704.1 General > 1704.1.1 Responsibilities > 1704.1.1.3 Responsibilities of the Permit Holder
1704.1.3 Structural Tests and Special Inspections, Responsibilities of the Permit Holder
The permit holder shall have the following duties and responsibilities: Statement of special inspections. The application for permit shall ...
NYC Building Code 2014 > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.1 General > 1704.1.3 Responsibilities of the Permit Holder
3308.4 Safeguards During Construction or Demolition, Responsibility and Supervision
The permit holder for the project, or where a permit is required by Section 3308.2, the holder of such permit, shall be responsible for complying ...
NYC Building Code 2022 > 33 Safeguards During Construction or Demolition > 3308 Unenclosed Perimeter Protection > 3308.4 Responsibility and Supervision
3308.4 Safeguards During Construction or Demolition, Responsibility and Supervision
The permit holder for the project, or where a permit is required by Section 3308.2, the permit holder of such, shall be responsible for complying ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3308 Protection of Unenclosed Perimeters > 3308.4 Responsibility and Supervision
*§28-204.1.1 Enforcement, Violations of Section 3321 of the New York City Building Code
code: The commissioner shall issue a notice of violation to the owner of such site, each permit holder responsible for ensuring that such worker ...
NYC General Admin. Provisions 2022 > 2 Enforcement > 204 Environmental Control Board > §28-204.1 General > *§28-204.1.1 Violations of Section 3321 of the New York City Building Code
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING