3314.2 Permit
JUMP TO FULL CODE CHAPTER
Prior to the installation and use of a scaffold, the contractor or licensee who is to install the scaffold, or a designated representative of the installer, shall obtain a permit for such scaffold.
Exceptions:
- A permit is not required for a two-point suspended scaffold suspended from a parapet using C-hooks.
- A permit is not required for a suspended scaffold provided:
- The scaffold is installed and used in conjunction with a construction, alteration, or demolition project that holds a valid permit from the department for such project;
- The site is closed to the public and enclosed with a fence in accordance with Section 3307; and
- The installation, use, and removal of the scaffold is confined within the site or over an area protected by sidewalk sheds or roof protection.
- Window washing equipment that is permanently anchored to the building or structure by a davit.
- A permit is not required for a supported scaffold, provided:
- The scaffold is not an outrigger scaffold (thrust out);
- No hoisting equipment with a manufacturer's rated capacity greater than 2,000 pounds (907 kg) will be located on the scaffold;
- The scaffold will not be loaded, or designed to be loaded, in excess of 75 pounds per square foot (366.15 kg/m2); and
- The scaffold is less than 40 feet (12 192 mm) in height.
Related Code Sections
Article **427 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work, Permits
All applications/permits issued to elevator contractors shall appear on the department of buildings website within forty-eight (48) hours of issuance ...
NYC General Admin. Provisions 2014 > 4 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work > **427 Permits
Article **427 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work, Permits
All applications/permits issued to elevator contractors shall appear on the department of buildings website within forty-eight (48) hours of issuance ...
NYC General Admin. Provisions 2022 > 4 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work > **427 Permits
Article 105 Administration, Permits
to be done unless and until a written permit therefore shall have been issued by the commissioner in accordance with the requirements of this code ...
Section 105 Administration, Permits
Permits shall comply with this section, with Article 105 of Chapter 1 of Title 28 of the Administrative Code , and with requirements found elsewhere ...
Section 105 Administration, Permits
Permits shall comply with this section, with Article 105 of Chapter 1 of Title 28 of the Administrative Code, and with requirements found elsewhere ...