• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.1438(a) Permanently Installed Overhead and Gantry Cranes

OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1438 Overhead & Gantry Cranes > 1926.1438(a) Permanently Installed Overhead and Gantry Cranes
JUMP TO FULL CODE CHAPTER
The requirements of § 1910.179, except for § 1910.179(b)(1), and not the requirements of this subpart CC, apply to the following equipment when used in construction and permanently installed in a facility: overhead and gantry cranes, including semigantry, cantilever gantry, wall cranes, storage bridge cranes, and others having the same fundamental characteristics.

Related Code Sections


1926.1438(a) Cranes & Derricks in Construction, Permanently Installed Overhead and Gantry Cranes
in construction and permanently installed in a facility: overhead and gantry cranes, including semigantry, cantilever gantry, wall cranes, storage ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1438 Overhead & Gantry Cranes > 1926.1438(a) Permanently Installed Overhead and Gantry Cranes
1926.1438(b)(2)(iii) Cranes & Derricks in Construction,
For equipment manufactured on or after September 19, 2001, the following sections of ASME B30.2-2005 (incorporated by reference, see § 1926.6) apply ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1438 Overhead & Gantry Cranes > 1926.1438(b) Overhead and Gantry Cranes That Are Not Permanently Installed in a Facility > 1926.1438(b)(2) > 1926.1438(b)(2)(iii)
1926.1438(b) Cranes & Derricks in Construction, Overhead and Gantry Cranes That Are Not Permanently Installed in a Facility
This paragraph applies to the following equipment when used in construction and not permanently installed in a facility: Overhead and gantry cranes ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1438 Overhead & Gantry Cranes > 1926.1438(b) Overhead and Gantry Cranes That Are Not Permanently Installed in a Facility
1926.1438(b)(2)(ii)(A) Cranes & Derricks in Construction,
Paragraphs (b)(5),(6),(7); (e)(1),(3),(5),(6); (f)(1),(4); (g); (h)(1),(3); (k); and (n) of § 1910.179 ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1438 Overhead & Gantry Cranes > 1926.1438(b) Overhead and Gantry Cranes That Are Not Permanently Installed in a Facility > 1926.1438(b)(2) > 1926.1438(b)(2)(ii) The Following Portions of § 1910.179: > 1926.1438(b)(2)(ii)(A)
1926.1438(b)(2)(ii)(B) Cranes & Derricks in Construction,
The definitions in § 1910.179(a) except for "hoist" and "load." For those words, the definitions in § 1926.1401 apply ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1438 Overhead & Gantry Cranes > 1926.1438(b) Overhead and Gantry Cranes That Are Not Permanently Installed in a Facility > 1926.1438(b)(2) > 1926.1438(b)(2)(ii) The Following Portions of § 1910.179: > 1926.1438(b)(2)(ii)(B)
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING