• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

605.1.1.1 Permanent Shading Devices for Fenestration

Green Construction Code 2012 of Maryland > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 605 Building Envelope Systems > 605.1 Prescriptive Compliance > 605.1.1 Insulation and Fenestration Criteria > 605.1.1.1 Permanent Shading Devices for Fenestration
JUMP TO FULL CODE CHAPTER
Vertical fenestration within 45 degrees (785 rad) of the nearest west, south, and east cardinal ordinate shall be shaded by permanent horizontal exterior projections with a projection factor greater than or equal to 0.25. Where different windows or glass doors have different projection factor values, each shall be evaluated separately, or an area-weighted projection factor value shall be calculated and used for all windows and glass doors. Horizontal projections shall extend laterally beyond the edge of the glazing not less than one-half of the height of the glazing, except at building corners.
Exception: Shading devices are not required for the following buildings and fenestrations:
  1. Buildings located in hurricane-prone regions in accordance with Section 1609.2 of the International Building Code or on any other building with a mean roof height exceeding the height limits specified in Table 1504.2 of the International Building Code based on the exposure category and basic wind speed at the building site.
  2. Where fenestration is located in a building wall that is within 18 inches (457 mm) of the lot line.
  3. Where equivalent shading of the fenestration is provided by buildings, structures, geological formations, or permanent exterior projections that are not horizontal, as determined by sun angle studies at the peak solar altitude on the spring equinox, and three hours before and after the peak solar altitude on the spring equinox.
  4. Where fenestration contains dynamic glazing that has a lower labeled solar heat gain coefficient (SHGC) equal to or less than 0.12, and the ratio of the higher and lower labeled visible transmittance (VT) is greater than or equal to 5. Dynamic glazing shall be automatically controlled to modulate, in multiple steps, the amount of solar gain and light transmitted into the space in response to daylight levels or solar intensity. Functional testing of controls shall be conducted in accordance with Section C408.3.1 of the International Energy Conservation Code.

Related Code Sections


605.1.1.1 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION, Permanent Shading Devices for Fenestration
Vertical fenestration within 45 degrees (785 rad) of the nearest west, south, and east cardinal ordinate shall be shaded by permanent horizontal ...
Green Construction Code 2012 of Maryland > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 605 Building Envelope Systems > 605.1 Prescriptive Compliance > 605.1.1 Insulation and Fenestration Criteria > 605.1.1.1 Permanent Shading Devices for Fenestration
C402.4.3 [CE] Commercial Energy Efficiency, Maximum U-factor and SHGC
measured horizontally from the furthest continuous extremity of any overhang, eave or permanently attached shading device to the vertical surface ...
Energy Conservation Code 2015 of Maryland > 4 [CE] Commercial Energy Efficiency > C402 Building Envelope Requirements > C402.4 Fenestration (Prescriptive) > C402.4.3 Maximum U-factor and SHGC
C402.4.3 [CE] Commercial Energy Efficiency, Maximum U-factor and SHGC
horizontally from the farthest continuous extremity of any overhang, eave or permanently attached shading device to the vertical surface of the glazing. B ...
Energy Conservation Code 2018 of Maryland > 4 [CE] Commercial Energy Efficiency > C402 Building Envelope Requirements > C402.4 Fenestration (Prescriptive) > C402.4.3 Maximum U-factor and SHGC
808.3.2.3 Indoor Environmental Quality and Comfort, Daylight Analysis
of exterior shading devices, buildings, structures, and geological formations on the fenestration of the proposed building and on the ground and other light ...
Green Construction Code 2012 of Maryland > 8 Indoor Environmental Quality and Comfort > 808 Daylighting > 808.3 Daylit Area of Building Spaces > 808.3.2 Daylight Performance Requirements > 808.3.2.3 Daylight Analysis
T103.5 [RE] Solar-Ready Provisions—Detached One- And Two-Family Dwellings and Townhouses, Shading
The solar-ready zone shall be set back from any existing or new, permanently affixed object on the building or site that is located south, east ...
Residential Code 2018 of Maryland > T [RE] Solar-Ready Provisions—Detached One- And Two-Family Dwellings and Townhouses > T103 (RA103) Solar-Ready Zone > T103.5 Shading
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING