Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

C403.10.2.1 Performance Standards (Mandatory)

Energy Conservation Code 2018 of Colorado > 4 [CE] Commercial Energy Efficiency > C403 Building Mechanical Systems > C403.10 Refrigeration Equipment Performance > C403.10.2 Walk-In Coolers and Walk-In Freezers (Mandatory) > C403.10.2.1 Performance Standards (Mandatory)
JUMP TO FULL CODE CHAPTER
Effective January 1, 2020, walk-in coolers and walk-in freezers shall meet the requirements of Tables C403.10.2.1(1), C403.10.2.1(2) and C403.10.2.1(3).
TABLE C403.10.2.1(1)
WALK-IN COOLER AND FREEZER DISPLAY DOOR EFFICIENCY REQUIREMENTSa
CLASS DESCRIPTORCLASSMAXIMUM ENERGY CONSUMPTION (kWh/day)a
Display door, medium temperatureDD, M0.04 x Add + 0.41
Display door, low temperatureDD, L0.15 x Add + 0.29
  1. Add is the surface area of the display door.
TABLE C403.10.2.1(2)
WALK-IN COOLER AND FREEZER NONDISPLAY DOOR EFFICIENCY REQUIREMENTSa
CLASS DESCRIPTORCLASSMAXIMUM ENERGY CONSUMPTION (kWh/day)a
Passage door, medium temperaturePD, M0.05 x And + 1.7
Passage door, low temperaturePD, L0.14 x And + 4.8
Freight door, medium temperatureFD, M0.04 x And + 1.9
Freight door, low temperatureFD, L0.12 x And + 5.6
  1. And is the surface area of the nondisplay door.
TABLE C403.10.2.1(3)
WALK-IN COOLER AND FREEZER REFRIGERATION SYSTEM EFFICIENCY REQUIREMENTS
CLASS DESCRIPTORCLASSMINIMUM ANNUAL WALK-IN ENERGY FACTOR AWEF
(Btu/W-h)
Dedicated condensing, medium temperature, indoor systemDC.M.I5.61
Dedicated condensing, medium temperature, indoor system,
> 9,000 Btu/h capacity
DC.M.I,
> 9,000
5.61
Dedicated condensing, medium temperature, outdoor systemDC.M.I7.60
Dedicated condensing, medium temperature, outdoor system,
> 9,000 Btu/h capacity
DC.M.I,
> 9,000
7.60

Related Code Sections


C403.10.2.1 [CE] Commercial Energy Efficiency, Performance Standards (Mandatory)
Effective January 1, 2020, walk-in coolers and walk-in freezers shall meet the requirements of Tables C403.10.2.1(1), C403.10.2.1(2 ...
Energy Conservation Code 2018 of Colorado > 4 [CE] Commercial Energy Efficiency > C403 Building Mechanical Systems > C403.10 Refrigeration Equipment Performance > C403.10.2 Walk-In Coolers and Walk-In Freezers (Mandatory) > C403.10.2.1 Performance Standards (Mandatory)
C407.2 [CE] Commercial Energy Efficiency, Mandatory Requirements
Compliance based on total building performance requires that a proposed design meet all of the following: The requirements of the sections ...
Energy Conservation Code 2021 of Colorado > 4 [CE] Commercial Energy Efficiency > C407 Total Building Performance > C407.2 Mandatory Requirements
R405.2 [RE] Residential Energy Efficiency, Mandatory Requirements
Compliance with this section requires that the mandatory provisions identified in Section R401.2 be met. Supply and return ducts not completely ...
Energy Conservation Code 2018 of Colorado > 4 [RE] Residential Energy Efficiency > R405 Simulated Performance Alternative (Performance) > R405.2 Mandatory Requirements
R405.2 [RE] Residential Energy Efficiency, Mandatory Requirements
Compliance with this section requires that the mandatory provisions identified in Section R401.2 be met. All supply and return ducts not completely ...
Energy Conservation Code 2015 of Colorado > 4 [RE] Residential Energy Efficiency > R405 Simulated Performance Alternative (Performance) > R405.2 Mandatory Requirements
C407.2 [CE] Commercial Energy Efficiency, Mandatory Requirements
Compliance with this section requires compliance with Sections C402.5, C403.2, C403.3 through C403.3.2, C403.4 through C403.4.2.3, C403.5.5, C403.7 ...
Energy Conservation Code 2018 of Colorado > 4 [CE] Commercial Energy Efficiency > C407 Total Building Performance > C407.2 Mandatory Requirements
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING