• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

315.4 Performance Qualification Testing

Ohio Plumbing Code 2011 > 3 General Regulations > 315 Welding and Brazing > 315.4 Performance Qualification Testing
JUMP TO FULL CODE CHAPTER
Each welder and brazer that performs a welding or brazing procedure as described in Section 315.2 shall be tested and qualified on that procedure as required in Section IX of the ASME Boiler and Pressure Vessel Code. The manufacturer or contractor, shall certify on the performance qualification record that the welder or brazer prepared and welded or brazed the test coupons in accordance with Section IX and that the test coupons were tested by an independent testing laboratory that has, on staff, a welding inspector certified by the "American Welding Society (AWS)."

Related Code Sections


313.4 General Regulations, Performance Qualification Testing
as required in Section IX of the "ASME Boiler and Pressure Vessel Code". The manufacturer or contractor shall certify on the performance qualification ...
Ohio Mechanical Code 2017 > 3 General Regulations > 313 Welding and Brazing > 313.4 Performance Qualification Testing
313.4 General Regulations, Performance Qualification Testing
Each welder or brazer that performs a welding or brazing procedure as described in Section 313.2 shall be tested and qualified on that procedure ...
Ohio Mechanical Code 2011 > 3 General Regulations > 313 Welding and Brazing > 313.4 Performance Qualification Testing
315.4 General Regulations, Performance Qualification Testing
Each welder and brazer that performs a welding or brazing procedure as described in Section 315.2 shall be tested and qualified on that procedure ...
Ohio Plumbing Code 2011 > 3 General Regulations > 315 Welding and Brazing > 315.4 Performance Qualification Testing
317.4 General Regulations, Performance Qualification Testing
Each welder and brazer that performs a welding or brazing procedure as described in Section 317.2 shall be tested and qualified on that procedure ...
Ohio Plumbing Code 2017 > 3 General Regulations > 317 Welding and Brazing > 317.4 Performance Qualification Testing
26.5.2 Supervising Station Alarm Systems, Indication of Remote Station Service
attesting to the responsibilities and qualifications of the parties performing the inspection, testing, and maintenance and accepting responsibility ...
National Fire Alarm and Signaling Code 2016 of Ohio > 26 Supervising Station Alarm Systems > 26.5 Remote Supervising Station Alarm Systems > 26.5.2 Indication of Remote Station Service
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING