• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2305.3.5.1 Perforated Shear Wall Segment Height Definition

2010 Building Code of NY > 23 Wood > 2305 General Design Requirements for Lateral-Force-Resisting Systems > 2305.3 Design of Wood Shear Walls > 2305.3.5 Shear Wall Height Definition > 2305.3.5.1 Perforated Shear Wall Segment Height Definition
JUMP TO FULL CODE CHAPTER
The height of a perforated shear wall segment, h, shall be defined as specified in Section 2305.3.5 for shear walls.

Related Code Sections


2305.3.5.1 Wood, Perforated Shear Wall Segment Height Definition
The height of a perforated shear wall segment, h , shall be defined as specified in Section 2305.3.5 for shear walls ...
2010 Building Code of NY > 23 Wood > 2305 General Design Requirements for Lateral-Force-Resisting Systems > 2305.3 Design of Wood Shear Walls > 2305.3.5 Shear Wall Height Definition > 2305.3.5.1 Perforated Shear Wall Segment Height Definition
Section 2302 Wood, Definitions
, perforated. Shear wall segment, perforated. STRUCTURAL COMPOSITE LUMBER. Laminated strand lumber (LSL). Laminated veneer ...
Building Code 2015 of New York State > 23 Wood > 2302 Definitions
2302.1 Wood, Definitions
, perforated. Shear wall segment, perforated. STRUCTURAL COMPOSITE LUMBER. Laminated strand lumber (LSL). Laminated veneer ...
Building Code 2015 of New York State > 23 Wood > 2302 Definitions > 2302.1 Definitions
2305.3.8.2.2 Wood, Perforated Shear Wall Resistance
for height-to-width ratios of perforated shear wall segments that do not exceed 2:1 for seismic forces and 3 1 / 2 :1 for other than seismic forces. For ...
2010 Building Code of NY > 23 Wood > 2305 General Design Requirements for Lateral-Force-Resisting Systems > 2305.3 Design of Wood Shear Walls > 2305.3.8 Shear Walls With Openings > 2305.3.8.2 Perforated Shear Walls > 2305.3.8.2.2 Perforated Shear Wall Resistance
2305.3.8 Wood, Shear Walls With Openings
with the following: The percentage of full-height sheathing shall be calculated as the sum of the widths of perforated shear wall segments divided ...
2010 Building Code of NY > 23 Wood > 2305 General Design Requirements for Lateral-Force-Resisting Systems > 2305.3 Design of Wood Shear Walls > 2305.3.8 Shear Walls With Openings
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING