• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1109.3 Penetration of Piping

Uniform Mechanical Code 2018 of Nevada > 11 Refrigeration > 1109.0 Refrigeration Piping, Containers, and Valves > 1109.3 Penetration of Piping
JUMP TO FULL CODE CHAPTER
Refrigerant piping shall not penetrate floors, ceilings, or roofs.
Exceptions:
  1. Penetrations connecting the basement and the first floor.
  2. Penetrations connecting the top floor and a machinery penthouse or roof installation.
  3. Penetrations connecting adjacent floors served by the refrigeration system.
  4. Penetrations of a direct system where the refrigerant concentration does not exceed that listed in Table 1102.3 for the smallest occupied space through which the refrigerant piping passes.
  5. In other than industrial occupancies and where the refrigerant concentration exceeds that listed in Table 1102.3 for the smallest occupied space, penetrations that connect separate pieces of equipment that are in accordance with one of the following:
    1. Enclosed by an approved gastight, fire-resistive duct or shaft with openings to those floors served by the refrigerating system.
    2. Located on the exterior wall of a building where vented to the outdoors or to the space served by the system and not used as an air shaft, closed court, or similar space. [ASHRAE 15:8.10.3]

Related Code Sections


1109.3 Refrigeration, Penetration of Piping
Refrigerant piping shall not penetrate floors, ceilings, or roofs. Exceptions: Penetrations connecting the basement and the first floor ...
Uniform Mechanical Code 2018 of Nevada > 11 Refrigeration > 1109.0 Refrigeration Piping, Containers, and Valves > 1109.3 Penetration of Piping
E 508.3 Sustainable Practices, Pipe Penetrations
Openings for pipe penetrations in walls, floors, and ceilings shall be larger than the penetrating pipe. Openings through concrete or masonry ...
Uniform Mechanical Code 2018 of Nevada > E Sustainable Practices > E 508.0 Installation > E 508.3 Pipe Penetrations
M2101.4 Hydronic Piping, Pipe Penetrations
Openings through concrete or masonry building elements shall be sleeved ...
Residential Code 2012 of Nevada > 21 Hydronic Piping > M2101 Hydronic Piping Systems Installation > M2101.4 Pipe Penetrations
M2101.4 Hydronic Piping, Pipe Penetrations
Openings through concrete or masonry building elements shall be sleeved ...
Residential Code 2018 of Nevada > 21 Hydronic Piping > M2101 Hydronic Piping Systems Installation > M2101.4 Pipe Penetrations
M2105.19 Hydronic Piping, Pipe Penetrations
Openings for pipe penetrations in walls, floors and ceilings shall be larger than the penetrating pipe. Openings through concrete or masonry building ...
Residential Code 2018 of Nevada > 21 Hydronic Piping > M2105 Ground-Source Heat-Pump System Loop Piping > M2105.19 Pipe Penetrations
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING