• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3101F.8.2 Peer Review

California Building Code 2016 (Vol 1 & 2) > 31F [SLC] Marine Oil Terminals > 3101F [SLC] Introduction > 3101F.8 Review Requirements > 3101F.8.2 Peer Review
JUMP TO FULL CODE CHAPTER
The Division may require peer review of advanced engineering analyses and designs, including, but not limited to, nonlinear dynamic structural analyses, alternative lateral force procedures, complex geotechnical evaluations, subsea pipeline analyses and designs, and fatigue analyses. Peer review shall be performed by an external independent source to maintain the integrity of the process.
The peer reviewer(s) and their affiliated organization shall have no other involvement in the project, except in a review capacity. The peer reviewer(s) shall be a California registered engineer(s) familiar with regulations governing the work and have technical expertise in the subject matter to a degree of at least that needed for the original work. The peer reviewer(s)' credentials shall be presented to the Division for approval prior to commencement of the review.
Upon completion of the review process, the peer reviewer(s) shall submit a written report directly to the Division that covers all aspects of the review process, including, but not limited to:
  1. Scope, extent and limitations of the review.
  2. Status of the documents reviewed at each stage (i.e. revision number and date).
  3. Findings.
  4. Recommended corrective actions and resolutions, if necessary.
  5. Conclusions.
  6. Certification by the peer reviewer(s), including whether or not the final reviewed work meets the requirements of this code.
  7. Formal documentation of important peer review correspondence, including requests for information and written responses.
The owner and operator shall cooperate in the review process, but shall not influence the peer review. If the original work requires modification after completion of the peer review, the final analyses and designs shall be submitted to the Division.

Related Code Sections


104.11.3 Scope and Administration, Peer Review
[OSHPD 1, 1R, 2, 4 & 5] When peer review is required for new or existing buildings, it shall be performed pursuant to Section 1617A.1.41 ...
California Building Code 2019 (Vol 1 & 2) > 1 Scope and Administration > 104 Duties and Powers of Building Official > 104.11 Alternative Materials, Design and Methods of Construction and Equipment > 104.11.3 Peer Review
3101F.8.2 [SLC] Marine Oil Terminals, Peer Review
The Division may require peer review of advanced engineering analyses and designs, including, but not limited to, nonlinear dynamic structural ...
California Building Code 2016 (Vol 1 & 2) > 31F [SLC] Marine Oil Terminals > 3101F [SLC] Introduction > 3101F.8 Review Requirements > 3101F.8.2 Peer Review
3101F.8.2 [SLC] Marine Oil Terminals, Peer Review
The Division may require peer review of advanced engineering analyses and designs, including, but not limited to, nonlinear dynamic structural ...
California Building Code 2019 (Vol 1 & 2) > 31F [SLC] Marine Oil Terminals > 3101F [SLC] Introduction > 3101F.8 Review Requirements > 3101F.8.2 Peer Review
1617A.1.41 Structural Design, Peer Review Requirements
[OSHPD 1, 1R, 2, 4, & 5] 1. General. Independent peer review is an objective technical review by knowledgeable reviewer(s ...
California Building Code 2019 (Vol 1 & 2) > 16A Structural Design > 1617A Modifications to ASCE 7 > 1617A.1 General > 1617A.1.41 Peer Review Requirements
1803A.8 Soils and Foundations, Geotechnical Peer Review
peer review by a California-licensed geotechnical engineer, in accordance with Section 322 of Part 10, Title 24, C.C.R., may be required ...
California Building Code 2016 (Vol 1 & 2) > 18A Soils and Foundations > 1803A Geotechnical Investigations > 1803A.8 Geotechnical Peer Review
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING