// CODE SNIPPET
13-26 Pedestrian Safety and Access
JUMP TO FULL CODE CHAPTER
For all accessory off-street parking facilities, the following safety features shall be provided at all vehicular exit points:
(a) a stop sign which shall be clearly visible to drivers. Such signage shall comply with the standards set forth in the Manual of Uniform Traffic Control Devices (MUTCD) issued by the Federal Highway Administration (FHWA) for a conventional single lane road; and
(b) a speed bump, which shall be located within the exit lane of the parking facility. Such speed bump shall:
(1) span the width of the vehicular travel lane;
(2) have a minimum height of two inches, as measured from the adjoining grade of the exit lane, and a maximum depth of 12 inches; and
(3) shall be located a minimum of four feet beyond the street line, as measured perpendicular to the street line.
Related Code Sections
3306.2 Safeguards During Construction or Demolition, Protection of Pedestrians and Adjoining Property
, 3308, and 3309. In addition, safety zones and measures to prevent access shall be
implemented as required by Sections 3306.2.1 and 3306.2.2 ...
NYC Building Code 2022 > 33 Safeguards During Construction or Demolition > 3306 Demolition > 3306.2 Protection of Pedestrians and Adjoining Property
703.9 Communication Elements and Features, Pedestrian Signals
Accessible pedestrian signals shall comply with Section 4E.06-Accessible Pedestrian Signals, and Section 4E.09-Accessible Pedestrian Signal Detectors ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 7 Communication Elements and Features > 703 Signs > 703.9 Pedestrian Signals
3109.4 Special Construction, Public Swimming Pools
Public swimming pools shall comply with the requirements for safety and accessibility as provided in Sections 3109.3 and 3109.4. Exceptions: A ...
NYC Building Code 2014 > 31 Special Construction > 3109 Swimming Pools, Swimming Pool Enclosures, and Safety Devices > 3109.4 Public Swimming Pools
Section 3307 Safeguards During Construction or Demolition, Protection of Pedestrians
and/or the ADA Accessibility Guidelines for Pedestrian Facilities in the Public Right-of-Way , as applicable ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3307 Protection of Pedestrians
3109.4 Special Construction, Public Swimming Pools
Public swimming pools shall comply with the requirements for safety and accessibility as provided in Sections 3109.3 and 3109.4.
Exception:
A ...
NYC Building Code 2022 > 31 Special Construction > 3109 Swimming Pools, Swimming Pool Enclosures, and Safety Devices > 3109.4 Public Swimming Pools