605.24 PE-RT Plastic
JUMP TO FULL CODE CHAPTER
Joints between polyethylene of raised temperature plastic tubing and fittings shall be in accordance with Section 605.24.1.
Mechanical joints shall be installed in accordance with the manufacturer's instructions. Fittings for polyethylene of raised temperature plastic tubing shall comply with the applicable standards indicated in Table 605.5 and shall be installed in accordance with the manufacturer's instructions. Polyethylene of raised temperature plastic tubing shall be factory marked with the applicable standards for the fittings that the manufacturer of the tubing specifies for use with the tubing.
Related Code Sections
605.24 Water Supply and Distribution, PE-RT Plastic
Joints between polyethylene of raised temperature plastic tubing and fittings shall be in accordance with Section 605.24.1 ...
Plumbing Code 2018 of Kansas > 6 Water Supply and Distribution > 605 Materials, Joints and Connections > 605.24 PE-RT Plastic
M2104.3 Hydronic Piping, Raised Temperature Polyethylene (PE-RT) Plastic Tubing
shall not occur within 18 inches (457 mm) of a transition from such metal pipe to PE-RT pipe ...
Residential Code 2018 of Kansas > 21 Hydronic Piping > M2104 Low Temperature Piping > M2104.3 Raised Temperature Polyethylene (PE-RT) Plastic Tubing
1203.14 Hydronic Piping, Raised Temperature Polyethylene (PE-RT) Plastic Tubing
mm) of a transition from such metal pipe to PE-RT pipe ...
Mechanical Code 2018 of Kansas > 12 Hydronic Piping > 1203 Joints and Connections > 1203.14 Raised Temperature Polyethylene (PE-RT) Plastic Tubing
1210.6.8 Hydronic Piping, Raised Temperature Polyethylene (PE-RT) Plastic Tubing
mm) of a transition from such metal pipe to PE-RT pipe ...
Mechanical Code 2018 of Kansas > 12 Hydronic Piping > 1210 Plastic Pipe Ground-Source Heat Pump Loop Systems > 1210.6 Joints > 1210.6.8 Raised Temperature Polyethylene (PE-RT) Plastic Tubing
M2105.13 Hydronic Piping, Raised Temperature Polyethylene (PE-RT) Plastic Tubing
(457 mm) of a transition from such metal pipe to PE-RT pipe or tubing ...
Residential Code 2018 of Kansas > 21 Hydronic Piping > M2105 Ground-Source Heat-Pump System Loop Piping > M2105.13 Raised Temperature Polyethylene (PE-RT) Plastic Tubing