• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

605.8 PE-RT

Uniform Plumbing Code 2018 of Nevada > 6 Water Supply and Distribution > 605.0 Joints and Connections > 605.8 PE-RT
JUMP TO FULL CODE CHAPTER
Polyethylene of raised temperature (PE-RT) tubing and fitting joining methods and shall comply with Section 605.8.1.

605.8.1 Mechanical Joints

Fittings for PE-RT tubing shall comply with the applicable standards listed in Table 604.1. Mechanical joints for PE-RT tubing shall be installed in accordance with the manufacturer's installation instructions.

Related Code Sections


605.8 Water Supply and Distribution, PE-RT
Polyethylene of raised temperature (PE-RT) tubing and fitting joining methods and shall comply with Section 605.8.1 ...
Uniform Plumbing Code 2018 of Nevada > 6 Water Supply and Distribution > 605.0 Joints and Connections > 605.8 PE-RT
E 506.11.2 Sustainable Practices, PE-RT-to-Metal Connections
Solder joints in a metal pipe shall not occur within 18 inches (457 mm) of a transition from such metal pipe to PE-RT pipe ...
Uniform Mechanical Code 2018 of Nevada > E Sustainable Practices > E 506.0 Joints and Connections > E 506.11 Raised Temperature Polyethylene (PE-RT) Plastic Tubing > E 506.11.2 PE-RT-to-Metal Connections
M2104.3.3 Hydronic Piping, PE-RT Insert Fittings
PE-RT insert fittings shall be installed in accordance with the manufacturer's instructions ...
Residential Code 2018 of Nevada > 21 Hydronic Piping > M2104 Low Temperature Piping > M2104.3 Raised Temperature Polyethylene (PE-RT) Plastic Tubing > M2104.3.3 PE-RT Insert Fittings
1211.10 Hydronics, Polyethylene of Raised Temperature (PE-RT)
Joints between polyethylene of raised temperature (PE-RT) tubing or fittings shall be installed with fittings for PE-RT tubing that comply ...
Uniform Mechanical Code 2018 of Nevada > 12 Hydronics > 1211.0 Joints and Connections > 1211.10 Polyethylene of Raised Temperature (PE-RT)
M2104.3.2 Hydronic Piping, PE-RT-To-Metal Connections
Solder joints in a metal pipe shall not occur within 18 inches (457 mm) of a transition from such metal pipe to PE-RT pipe ...
Residential Code 2012 of Nevada > 21 Hydronic Piping > M2104 Low Temperature Piping > M2104.3 Raised Temperature Polyethylene (PE-RT) Plastic Tubing > M2104.3.2 PE-RT-To-Metal Connections
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING