• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

605.7 PE-AL-PE Plastic Pipe/Tubing and Joints

2021 Oregon Plumbing Specialty Code > 6 Water Supply and Distribution > 605.0 Joints and Connections > 605.7 PE-AL-PE Plastic Pipe/Tubing and Joints
JUMP TO FULL CODE CHAPTER
PE-AL-PE plastic pipe or tubing and fitting joining methods shall be installed in accordance with the manufacturer's installation instructions and shall comply with Section 605.7.1 and Section 605.7.1.1.

605.7.1 Mechanical Joints

Mechanical joints for PE-AL-PE pipe or tubing and fittings shall be either of the metal insert fittings with a split ring and compression nut or metal insert fittings with copper crimp rings. Metal insert fittings shall comply with ASTM F1974. Crimp insert fittings shall be joined to the pipe by placing the copper crimp ring around the outer circumference of the pipe, forcing the pipe material into the space formed by the ribs on the fitting until the pipe contacts the shoulder of the fitting. The crimp ring shall then be positioned on the pipe so the edge of the crimp ring is 1/8 of an inch (3.2 mm) to 1/4 of an inch (6.4 mm) from the end of the pipe. The jaws of the crimping tool shall be centered over the crimp ring and tool perpendicular to the barb. The jaws shall be closed around the crimp ring and shall not be crimped more than once.

605.7.1.1 Compression Joints

Compression joints for PE-AL-PE pipe or tubing and fittings shall be joined through the compression of a split ring, by a compression nut around the circumference of the pipe. The compression nut and split ring shall be placed around the pipe. The ribbed end of the fitting shall be inserted into the pipe until the pipe contacts the shoulder of the fitting. Position and compress the split ring by tightening the compression nut onto the insert fitting.

Related Code Sections


605.7 Water Supply and Distribution, PE-AL-PE Plastic Pipe/Tubing and Joints
PE-AL-PE plastic pipe or tubing and fitting joining methods shall be installed in accordance with the manufacturer's installation instructions ...
2021 Oregon Plumbing Specialty Code > 6 Water Supply and Distribution > 605.0 Joints and Connections > 605.7 PE-AL-PE Plastic Pipe/Tubing and Joints
Section P2906 Water Supply and Distribution, Materials, Joints and Connections
-AL-PE) pipe ASTM F1282; CSA B137.9 Polyethylene (PE) plastic pipe ASTM D2104; ASTM D2239; AWWA C901; CSA B137.1 ...
2021 Oregon Residential Specialty Code (ORSC) > 29 Water Supply and Distribution > P2906 Materials, Joints and Connections
M2104.4.2 Hydronic Piping, PE-AL-PE-To-Metal Connections
Solder joints in a metal pipe shall not occur within 18 inches (457 mm) of a transition from such metal pipe to PE-AL-PE pipe ...
2021 Oregon Residential Specialty Code (ORSC) > 21 Hydronic Piping > M2104 Low Temperature Piping > M2104.4 Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Pressure Pipe > M2104.4.2 PE-AL-PE-To-Metal Connections
1203.15.2 Hydronic Piping, PE-AL-PE-To-Metal Connections
Solder joints in a metal pipe shall not occur within 18 inches (457 mm) of a transition from such metal pipe to PE-AL-PE pipe ...
2019 Oregon Mechanical Specialty Code > 12 Hydronic Piping > 1203 Joints and Connections > 1203.15 Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Pressure Pipe > 1203.15.2 PE-AL-PE-To-Metal Connections
P2906.4 Water Supply and Distribution, Water Service Pipe
/aluminum/high-density polyethylene (PEX-AL-HDPE) pipe ASTM F1986 Cross-linked polyethylene (PEX) plastic tubing ASTM F876 ...
2021 Oregon Residential Specialty Code (ORSC) > 29 Water Supply and Distribution > P2906 Materials, Joints and Connections > P2906.4 Water Service Pipe
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING