• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

§28-116.5 Payment of Outstanding Penalties

NYC General Admin. Provisions 2014 > 1 Administration > 116 Inspections and Sign-Off of Completed Work > §28-116.5 Payment of Outstanding Penalties
JUMP TO FULL CODE CHAPTER
The department may refuse to issue a letter of completion or certificate of occupancy pending payment of all outstanding fines or civil penalties imposed for violations of this code, the 1968 building code or other laws enforced by the department at the same building.

Related Code Sections


§28-116.5 Administration, Payment of Outstanding Penalties
The department may refuse to issue a letter of completion or certificate of occupancy pending payment of all outstanding fines or civil penalties ...
NYC General Admin. Provisions 2008 > 1 Administration > 116 Inspections and Sign-Off of Completed Work > §28-116.5 Payment of Outstanding Penalties
§28-116.5 Administration, Payment of Outstanding Penalties
The department may refuse to issue a letter of completion or certificate of occupancy pending payment of all outstanding fines or civil penalties ...
NYC General Admin. Provisions 2014 > 1 Administration > 116 Inspections and Sign-Off of Completed Work > §28-116.5 Payment of Outstanding Penalties
§28-116.5 Administration, Payment of Outstanding Penalties
The department may refuse to issue a letter of completion or certificate of occupancy pending payment of all outstanding fines or civil penalties ...
NYC General Admin. Provisions 2022 > 1 Administration > 116 Inspections and Sign-Off of Completed Work > §28-116.5 Payment of Outstanding Penalties
§28-118.14 Administration, Payment of Outstanding Penalties
The department may refuse to issue a certificate of occupancy for a building pending payment of all outstanding fines or civil penalties imposed ...
NYC General Admin. Provisions 2008 > 1 Administration > 118 Certificates of Occupancy > §28-118.14 Payment of Outstanding Penalties
§28-118.14 Administration, Payment of Outstanding Penalties
The department may refuse to issue a certificate of occupancy for a building pending payment of all outstanding fines or civil penalties imposed ...
NYC General Admin. Provisions 2014 > 1 Administration > 118 Certificates of Occupancy > §28-118.14 Payment of Outstanding Penalties
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING