• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 1917 Paving

NYC Building Code 2014 > 19 Concrete > 1917 Paving
JUMP TO FULL CODE CHAPTER

1917.1 Definitions

The following words and terms shall, for the purposes of this section, have the meanings shown herein.

ASPHALT. A dark brown to black bitumen pitch that melts readily and which appears in nature in asphalt beds or is produced as a by-product of the petroleum industry.

ASPHALTIC CONCRETE or ASPHALT PAVING. A mixture of liquid asphalt and graded aggregate used as a paving material.

I-4 MIX. A type of heavy duty asphaltic concrete mix containing 0.75 inch (19 mm) nominal maximum size aggregate with 25 percent to 50 percent of the aggregate capable of passing through a No. 8 sieve and in which all sand contained in the mix is crushed.

RECLAIMED ASPHALT PAVEMENT. Asphalt pavement that has been processed for reuse in asphaltic concrete.

1917.2 Reclaimed Asphalt Pavement Content in Asphaltic Concrete

On and after January 1, 2015, asphaltic concrete, other than I-4 mix or other approved heavy duty asphaltic concrete mix, shall contain not less than 30 percent reclaimed asphalt pavement, as measured by weight. I-4 mix or other approved heavy duty asphaltic concrete mix shall contain not less than 10 percent reclaimed asphalt pavement, as measured by weight. Reclaimed asphalt paving used in asphaltic concrete shall comply with ASTM D 692 or ASTM 1073.

Exceptions:
  1. Asphaltic concrete used in a project where the content of asphaltic concrete is governed by a federal or state law, rule, regulation, guideline, or specification that requires a different composition.
  2. Asphaltic concrete used for runways, taxiways, or other surfaces utilized by aircraft.
  3. The commissioner may waive compliance with this section if the commissioner, after consulting with the commissioner of transportation and the owners or persons in charge of all asphalt plants located within the city, finds that a sufficient supply of reclaimed asphalt pavement is not available.

Related Code Sections


Article 13 Structural Work, Paving
or ASPHALT PAVING. A mixture of liquid asphalt and graded aggregate used as a paving material. I-4 MIX. A type of heavy duty asphaltic concrete mix ...
NYC 1968 Code (Vol I) > 10 Structural Work > 13 Paving
Section 1917 Concrete, Paving
or ASPHALT PAVING. A mixture of liquid asphalt and graded aggregate used as a paving material. I-4 MIX. A type of heavy duty asphaltic concrete ...
NYC Building Code 2014 > 19 Concrete > 1917 Paving
Section 1918 Concrete, Paving
concrete mix shall contain not less than 10 percent reclaimed asphalt pavement, as measured by weight. Reclaimed asphalt paving used in asphaltic ...
NYC Building Code 2008 > 19 Concrete > 1918 Paving
Section 1913 Concrete, Asphalt Paving
The following terms are defined in Chapter 2. ASPHALT. ASPHALTIC CONCRETE or ASPHALT PAVING. I-4 MIX. RECLAIMED ASPHALT PAVEMENT ...
NYC Building Code 2022 > 19 Concrete > 1913 Asphalt Paving
1913.2 Concrete, Reclaimed Asphalt Pavement Content in Asphaltic Concrete
pavement, as measured by weight. Reclaimed asphalt paving used in asphaltic concrete shall comply with ASTM D692 or ASTM D1073. Exceptions ...
NYC Building Code 2022 > 19 Concrete > 1913 Asphalt Paving > 1913.2 Reclaimed Asphalt Pavement Content in Asphaltic Concrete
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING