21.406.2 Particular Feature Units
JUMP TO FULL CODE CHAPTER
For particular feature units, dimensions shall be in accordance with the following:
- For molded face units, no overall dimension (width, height and length) shall differ by more than 1/8 inch (3.2 mm) from the specified standard dimension. Dimensions of molded features (ribs, scores, hex-shapes, patterns, etc.) shall be within 1/16 inch (1.6 mm) of the specified standard dimensions and shall be within 1/16 inch (1.6 mm) of the specified placement of the unit.
- For split-faced units, all non-split overall dimensions (width, height and length) shall differ by no more than 1/8 inch (3.2 mm) from the specified standard dimensions. On faces that are split, overall dimensions will vary. Local suppliers should be consulted to determine dimensional tolerances achievable.
- For slumped units, no overall height dimension shall differ by more than 1/8 inch (3.2 mm) from the specified standard dimension. On faces that are slumped, overall dimensions will vary. Local suppliers should be consulted to determine dimension tolerances achievable.
Note: Standard dimensions of units are the manufacturer's designated dimensions. Nominal dimensions of modular size units, except slumped units, are equal to the standard dimensions plus 3/8 inch (9.5 mm), the thickness of one standard mortar joint. Slumped units are equal to the standard dimensions plus 1/2 inch (13 mm), the thickness of one standard mortar joint. Nominal dimensions of nonmodular size units usually exceed the standard dimensions by 1/8 inch to 1/4 inch (3.2 mm to 6.4 mm).
Related Code Sections
21.406.2 Referenced Standards, Particular Feature Units
For particular feature units, dimensions shall be in accordance with the following: For molded face units, no overall dimension (width, height ...
California Existing Building Code 2016 > Referenced Standards > 21-4 Hollow and Solid Load-Bearing Concrete Masonry Units > 21.406 — Permissible Variations in Dimensions > 21.406.2 Particular Feature Units
11B-233.3.2 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Residential Dwelling Units for Sale
of particular residential dwelling units take place only after a
specific buyer has been identified. In such programs,
the covered entity must provide the units ...
California Building Code 2019 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-233 Public Housing Facilities > 11B-233.3 Public Housing Facilities > 11B-233.3.2 Residential Dwelling Units for Sale
11B-233.3.1.2.6.3 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Test Number Two, Site Analysis Test
, or ground floor units served by a
particular entrance on an accessible route defined by a calculation of the straight line
slope not exceeding 8.33 percent ...
California Building Code 2019 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-233 Public Housing Facilities > 11B-233.3 Public Housing Facilities > 11B-233.3.1 Minimum Number: New Construction > 11B-233.3.1.2 Residential Dwelling Units With Adaptable Features > 11B-233.3.1.2.6 Public Housing Facility Site Impracticality > 11B-233.3.1.2.6.3 Test Number Two, Site Analysis Test
11B-233.3.2.1 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Buyer Identified Residential Dwelling Units for Sale
of particular residential dwelling units take place only after a
specific buyer has been identified. In such programs,
the covered entity must provide the units ...
California Building Code 2019 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-233 Public Housing Facilities > 11B-233.3 Public Housing Facilities > 11B-233.3.2 Residential Dwelling Units for Sale > 11B-233.3.2.1 Buyer Identified Residential Dwelling Units for Sale
11B-233.3.1.2 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Residential Dwelling Units With Adaptable Features
in a building, or ground floor units served by a particular entrance, not on an accessible route
shall comply with the features listed in Section 11B ...
California Building Code 2019 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-233 Public Housing Facilities > 11B-233.3 Public Housing Facilities > 11B-233.3.1 Minimum Number: New Construction > 11B-233.3.1.2 Residential Dwelling Units With Adaptable Features