• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

A505.2.3 Partially Grouted Masonry

2010 Existing Building Code of NY > A5 Earthquake Hazard Reduction in Existing Concrete Buildings and Concrete With Masonry Infill Buildings > A505 General Requirements > A505.2 Properties of In-Place Materials > A505.2.3 Partially Grouted Masonry
JUMP TO FULL CODE CHAPTER
A minimum of five units shall be removed from the walls and tested in conformance with ASTM C 90. Compressive strength of the masonry is permitted to be determined in accordance with Tables 2105.2.2.1.1 and 2105.2.2.1.2 of the Building Code of New York State , assuming Type S mortar. The strain associated with peak stress may be taken as 0.0025.

Related Code Sections


A505.2.3 Earthquake Hazard Reduction in Existing Concrete Buildings and Concrete With Masonry Infill Buildings, Partially Grouted Masonry
A minimum of five units shall be removed from the walls and tested in conformance with ASTM C 90. Compressive strength of the masonry is permitted ...
2010 Existing Building Code of NY > A5 Earthquake Hazard Reduction in Existing Concrete Buildings and Concrete With Masonry Infill Buildings > A505 General Requirements > A505.2 Properties of In-Place Materials > A505.2.3 Partially Grouted Masonry
2105.2.1 Masonry, Compliance With f ' m and f ' AAC
or exceeds the value of f ' m for clay and concrete masonry and f ' AAC for AAC masonry. For partially grouted clay and concrete masonry ...
2010 Building Code of NY > 21 Masonry > 2105 Quality Assurance > 2105.2 Acceptance Relative to Strength Requirements > 2105.2.1 Compliance With f ' m and f ' AAC
R606.3.5.3 Wall Construction, Construction
Requirements for grouted masonry construction shall be as follows: Masonry shall be built to preserve the unobstructed vertical continuity ...
2020 Residential Code of New York State > 6 Wall Construction > R606 General Masonry Construction > R606.3 Construction Requirements > R606.3.5 Grouting Requirements > R606.3.5.3 Construction
R606.3.5.3 Wall Construction, Construction
Requirements for grouted masonry construction shall be as follows: Masonry shall be built to preserve the unobstructed vertical continuity ...
Residential Code 2015 of New York State > 6 Wall Construction > R606 General Masonry Construction > R606.3 Construction Requirements > R606.3.5 Grouting Requirements > R606.3.5.3 Construction
722.3.1.2 Fire and Smoke Protection Features, Ungrouted or Partially Grouted Construction
T e shall be the value obtained for the concrete masonry unit determined in accordance with ASTM C140 ...
2020 Building Code of New York State > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.3 Concrete Masonry > 722.3.1 Equivalent Thickness > 722.3.1.2 Ungrouted or Partially Grouted Construction
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING