Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

705.11.1 Parapet Construction

Building Code 2021 of Illinois > 7 Fire and Smoke Protection Features > 705 Exterior Walls > 705.11 Parapets > 705.11.1 Parapet Construction
JUMP TO FULL CODE CHAPTER
Parapets shall have the same fire-resistance rating as that required for the supporting wall, and on any side adjacent to a roof surface, shall have noncombustible faces for the uppermost 18 inches (457 mm), including counterflashing and coping materials. The height of the parapet shall be not less than 30 inches (762 mm) above the point where the roof surface and the wall intersect. Where the roof slopes toward a parapet at a slope greater than 2 units vertical in 12 units horizontal (16.7-percent slope), the parapet shall extend to the same height as any portion of the roof within a fire separation distance where protection of wall openings is required, but the height shall be not less than 30 inches (762 mm).

Related Code Sections


705.11.1 Fire and Smoke Protection Features, Parapet Construction
Parapets shall have the same fire-resistance rating as that required for the supporting wall, and on any side adjacent to a roof surface, shall ...
Building Code 2021 of Illinois > 7 Fire and Smoke Protection Features > 705 Exterior Walls > 705.11 Parapets > 705.11.1 Parapet Construction
705.11.1 Fire and Smoke Protection Features, Parapet Construction
Parapets shall have the same fire-resistance rating as that required for the supporting wall, and on any side adjacent to a roof surface, shall ...
Building Code 2018 of Illinois > 7 Fire and Smoke Protection Features > 705 Exterior Walls > 705.11 Parapets > 705.11.1 Parapet Construction
2109.2.4.3 Masonry, Parapet Walls
Parapet walls constructed of adobe units shall be waterproofed ...
Building Code 2021 of Illinois > 21 Masonry > 2109 Empirical Design of Adobe Masonry > 2109.2 Adobe Construction > 2109.2.4 Detailed Requirements > 2109.2.4.3 Parapet Walls
2109.2.4.3 Masonry, Parapet Walls
Parapet walls constructed of adobe units shall be waterproofed ...
Building Code 2018 of Illinois > 21 Masonry > 2109 Empirical Design of Adobe Masonry > 2109.2 Adobe Construction > 2109.2.4 Detailed Requirements > 2109.2.4.3 Parapet Walls
906.6 Alterations—Level 3, Bracing for Unreinforced Masonry Parapets
Parapets constructed of unreinforced masonry in buildings assigned to Seismic Design Category C, D, E or F shall have bracing installed as needed ...
Existing Building Code 2021 of Illinois > 9 Alterations—Level 3 > 906 Structural > 906.6 Bracing for Unreinforced Masonry Parapets
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING