606.2.2 Parapet Bracing and Wall Anchors for Reroof Permits
JUMP TO FULL CODE CHAPTER
Unreinforced masonry bearing wall buildings classified as Seismic Design Category D, E, or F shall have parapet bracing and wall anchors installed at the roof line whenever a reroofing permit is issued. Such parapet bracing and wall anchors shall be designed in accordance with the reduced Building Code of New York State level seismic forces as specified in Section 506.1.1.3 and design procedures of Section 506.1.1.1.
Related Code Sections
606.2.2 Alterations - Level 1, Parapet Bracing and Wall Anchors for Reroof Permits
at the roof line whenever a reroofing permit is issued. Such parapet bracing and wall anchors shall be designed in accordance with the reduced Building ...
2010 Existing Building Code of NY > 6 Alterations - Level 1 > 606 Structural > 606.2 Design Criteria > 606.2.2 Parapet Bracing and Wall Anchors for Reroof Permits
A113.6 Guidelines for the Seismic Retrofit of Existing Buildings, Parapets
Parapets and exterior wall appendages not conforming to this chapter shall be removed, or stabilized or braced to ensure that the parapets ...
2020 Existing Building Code of NYS > A Guidelines for the Seismic Retrofit of Existing Buildings > A113 Detailed Building System Design Requirements > A113.6 Parapets
A113.6 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings, Parapets
Parapets and exterior wall appendages not conforming to this chapter shall be removed, or stabilized or braced to ensure that the parapets ...
2010 Existing Building Code of NY > A1 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings > A113 Detailed System Design Requirements > A113.6 Parapets
A113.6 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings, Parapets
Parapets and exterior wall appendages not conforming to this chapter shall be removed, or stabilized or braced to ensure that the parapets ...
Existing Building Code 2015 of New York State > A1 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings > A113 Detailed System Design Requirements > A113.6 Parapets