• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

11B-406.3 Parallel Curb Ramps

California Building Code 2016 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-406 Curb Ramps, Blended Transitions and Islands > 11B-406.3 Parallel Curb Ramps
JUMP TO FULL CODE CHAPTER
Parallel curb ramps shall comply with Sections 11B-406.3 and 11B-406.5.

11B-406.3.1 Slope

The running slope of the curb ramp segments shall be in-line with the direction of sidewalk travel. Ramp runs shall have a running slope not steeper than 1:12.

11B-406.3.2 Turning Space

A turning space 48 inches (1219 mm) minimum by 48 inches (1219 mm) minimum shall be provided at the bottom of the curb ramp. The slope of the turning space in all directions shall be 1:48 maximum.
FIGURE 11B-406.3.2
PARALLEL CURB RAMPS

Related Code Sections


11B-406.1.2 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Parallel Curb Ramps
Parallel curb ramps shall comply with Section 11B -406.3 ...
California Building Code 2016 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-406 Curb Ramps, Blended Transitions and Islands > 11B-406.1 General > 11B-406.1.2 Parallel Curb Ramps
11B-406.1.2 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Parallel Curb Ramps
Parallel curb ramps shall comply with Section 11B-406.3 ...
California Building Code 2019 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-406 Curb Ramps, Blended Transitions and Islands > 11B-406.1 General > 11B-406.1.2 Parallel Curb Ramps
11B-406.3 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Parallel Curb Ramps
Parallel curb ramps shall comply with Sections 11B-406.3 and 11B-406.5. A parallel curb ramp may be provided with one sloping segment or two opposing ...
California Building Code 2019 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-406 Curb Ramps, Blended Transitions and Islands > 11B-406.3 Parallel Curb Ramps
11B-705.1.2.2.2 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Parallel Curb Ramps
Detectable warnings at parallel curb ramps shall be located so the edge nearest the curb is 6 inches (152 mm) minimum and 8 inches (203 mm) maximum ...
California Building Code 2019 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-705 Detectable Warnings and Detectable Directional Texture > 11B-705.1 Detectable Warnings > 11B-705.1.2 Locations > 11B-705.1.2.2 Curb Ramps > 11B-705.1.2.2.2 Parallel Curb Ramps
11B-406.1 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, General
Curb ramps, blended transitions and islands on accessible routes shall comply with Section 11B- 406. Curb ramps may be perpendicular, parallel ...
California Building Code 2019 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-406 Curb Ramps, Blended Transitions and Islands > 11B-406.1 General
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING