• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

P102.8.2.3 Parallel and Forward Approach

NYC Building Code 2014 > P Type B+NYC Unit Toilet and Bathing Rooms Requirements > P102 Toilet and Bathing Rooms > P102.8 Water Closet > P102.8.2 Clearance > P102.8.2.3 Parallel and Forward Approach
JUMP TO FULL CODE CHAPTER
Where both a parallel and a forward approach are provided to the water closet, the clearance shall be 56 inches (1420 mm) minimum, measured perpendicular from the rear wall, and 60 inches (1524 mm) minimum, measured perpendicular from the side wall. No fixtures or obstructions, other than the water closet, shall be within the clearance.

Related Code Sections


1107.2.2.7.2.3 Accessibility, Parallel and Forward Approach
Where both a parallel and a forward approach are provided to the water closet, the clearance shall be 56 inches (1422 mm) minimum, measured ...
NYC Building Code 2022 > 11 Accessibility > 1107 Dwelling Units and Sleeping Units > 1107.2 Design > 1107.2.2 Type B+NYC Unit Toilet and Bathing Rooms > 1107.2.2.7 Water Closet > 1107.2.2.7.2 Clearance > 1107.2.2.7.2.3 Parallel and Forward Approach
P102.8.2.3 Type B+NYC Unit Toilet and Bathing Rooms Requirements, Parallel and Forward Approach
Where both a parallel and a forward approach are provided to the water closet, the clearance shall be 56 inches (1420 mm) minimum, measured ...
NYC Building Code 2014 > P Type B+NYC Unit Toilet and Bathing Rooms Requirements > P102 Toilet and Bathing Rooms > P102.8 Water Closet > P102.8.2 Clearance > P102.8.2.3 Parallel and Forward Approach
P102.8.2.3 R-2 Occupancy Toilet and Bathing Facilities Requirements, Parallel and Forward Approach
Where both a parallel and a forward approach are provided to the water closet, the clearance shall be 56 inches (1420 mm) minimum, measured ...
NYC Building Code 2008 > P R-2 Occupancy Toilet and Bathing Facilities Requirements > P102 Toilet and Bathing Facilities > P102.8 Water Closet > P102.8.2 Clearance > P102.8.2.3 Parallel and Forward Approach
1004.12.2 Dwelling Units and Sleeping Units, Clear Floor Space
A clear floor space, positioned for a parallel or forward approach to the dishwasher, shall ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 10 Dwelling Units and Sleeping Units > 1004 Type B Units > 1004.12 Kitchens and Kitchenettes > 1004.12.2 Clear Floor Space
1003.12.5.4.1 Dwelling Units and Sleeping Units, Approach
A clear floor space, positioned for a parallel or forward approach to the cooktop, shall be provided ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 10 Dwelling Units and Sleeping Units > 1003 Type A Units > 1003.12 Kitchens and Kitchenettes > 1003.12.5 Appliances > 1003.12.5.4 Cooktop > 1003.12.5.4.1 Approach
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING