5.2.1 Panel-To-Panel Connections
JUMP TO FULL CODE CHAPTER
Adjacent wall panels are not connected by welded steel inserts.
For conforming buildings, the evaluator may consider this condition as mitigated, and no calculations are necessary. The deficiency is in the strength of the inserts. Check the welded inserts. Determine where connection failures would be brittle (e.g., pull-out of an embedded item would occur before yield of a mild steel element). Analyze structure for stability assuming that these brittle connections have failed or are not capable of transmitting forces or check such connections for seismic force amplified by the factor Cd/2, but not less than 1.5.
Related Code Sections
5.2.1 Seismic Evaluation Procedures for Hospital Buildings, Panel-To-Panel Connections
Adjacent wall panels are not connected by welded steel inserts. For conforming buildings, the evaluator may consider this condition as mitigated ...
California Administrative Code 2016 > 6 Seismic Evaluation Procedures for Hospital Buildings > 5 Procedures for Shear Walls > 5.2 Precast Concrete Shear Walls > 5.2.1 Panel-To-Panel Connections
5.2.1 Seismic Evaluation Procedures for Hospital Buildings, Panel-To-Panel Connections
Adjacent wall panels are not connected by welded steel inserts. For conforming buildings, the evaluator may consider this condition as mitigated ...
California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 5 Procedures for Shear Walls > 5.2 Precast Concrete Shear Walls > 5.2.1 Panel-To-Panel Connections
R610.5.3 Wall Construction, Panel-To-Panel Connection
SIPs shall be connected at vertical in-plane joints in accordance with Figure R610.8 or by other approved methods ...
California Residential Code 2019 > 6 Wall Construction > R610 Structural Insulated Panel Wall Construction > R610.5 Wall Construction > R610.5.3 Panel-To-Panel Connection
R602.10.8 Wall Construction, Braced Wall Panel Connections
WALL PANEL CONNECTION WHEN PERPENDICULAR TO FLOOR/CEILING FRAMING For SI: 1 inch = 25.4 mm. FIGURE R602.10.8(2) BRACED WALL PANEL CONNECTION ...
California Residential Code 2016 > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.8 Braced Wall Panel Connections
R602.10.8 Wall Construction, Braced Wall Panel Connections
R602.10.8(1)
BRACED WALL PANEL CONNECTION WHEN PERPENDICULAR TO FLOOR/CEILING FRAMING
For SI: 1 inch = 25.4 mm.
FIGURE R602.10.8(2 ...
California Residential Code 2019 > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.8 Braced Wall Panel Connections