Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2110.3 Panel Size

NYC Building Code 2008 > 21 Masonry > 2110 Glass Unit Masonry > 2110.3 Panel Size
JUMP TO FULL CODE CHAPTER

2110.3.1 Exterior Standard-Unit Panels

The maximum area of each individual exterior standard-unit panel shall be 144 square feet (13.4 m2) when the design wind pressure is 20 psf (958 N/m2). The maximum panel dimension between structural supports shall be 25 feet (7620 mm) in width or 20 feet (6096 mm) in height. The panel areas are permitted to be adjusted in accordance with Figure 2110.3.1 for other wind pressures.


For SI: 1 square foot = 0.0929 m2, 1 pound per square foot = 47.9 N/m2.
FIGURE 2110.3.1
GLASS MASONRY DESIGN WIND LOAD RESISTANCE

2110.3.2 Exterior Thin-Unit Panels

The maximum area of each individual exterior thin-unit panel shall be 85 square feet (7.9 m2). The maximum dimension between structural supports shall be 15 feet (4572 mm) in width or 10 feet (3048 mm) in height. Thin units shall not be used in applications where the design wind pressure exceeds 20 psf (958 N/m2).

2110.3.3 Interior Panels

The maximum area of each individual standard-unit panel shall be 250 square feet (23.2 m2). The maximum area of each thin-unit panel shall be 150 square feet (13.9 m2). The maximum dimension between structural supports shall be 25 feet (7620 mm) in width or 20 feet (6096 mm) in height.

2110.3.4 Solid Units

The maximum area of solid glass-block wall panels in both exterior and interior walls shall not be more than 100 square feet (9.3 m2).

2110.3.5 Curved Panels

The width of curved panels shall conform to the requirements of Sections 2110.3.1, 2110.3.2 and 2110.3.3, except additional structural supports shall be provided at locations where a curved section joins a straight section, and at inflection points in multi-curved walls.

Related Code Sections


2110.3 Masonry, Panel Size
The maximum area of each individual exterior standard-unit panel shall be 144 square feet (13.4 m 2 ) when the design wind pressure is 20 psf (958 N ...
NYC Building Code 2008 > 21 Masonry > 2110 Glass Unit Masonry > 2110.3 Panel Size
8.7.5.9.3 General Requirements, Car Top Protection
The car top access panel size requirements in 5.9.14.1(b) do not apply where the existing car top is retained. The dimensions of the existing car top ...
Safety Code for Elevators and Escalators 2013 of New York City > 8 General Requirements > 8.7 Alterations > 8.7.5 Alterations to Special Application Elevators > 8.7.5.9 Mine Elevators > 8.7.5.9.3 Car Top Protection
8.7.5.9 General Requirements, Mine Elevators
The car top access panel size requirements in 5.9.14.1(b) do not apply where the existing car top is retained. The dimensions of the existing car ...
Safety Code for Elevators and Escalators 2013 of New York City > 8 General Requirements > 8.7 Alterations > 8.7.5 Alterations to Special Application Elevators > 8.7.5.9 Mine Elevators
H107.2 Outdoor Signs, Glass Panels
Glass panels used in display areas of signs shall be limited in size, thickness and type of glass as provided by Table H107.2 ...
NYC Building Code 2008 > H Outdoor Signs > H107 Material Limitations > H107.2 Glass Panels
1401.2 Exterior Walls, Construction Documents
This shall include section and elevation drawings that identify materials and components of the tested assembly, including panel sizes and joint ...
NYC Building Code 2022 > 14 Exterior Walls > 1401 General > 1401.2 Construction Documents
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.